Unit is marked with the following symbols:
This symbol indicates that electrical and electronic products must
not be mixed with unsorted household waste. Do not attempt to
dismantle the system on your own. All works involved in dismantling
the system, handling the refrigerant, oil and other components must
be carried out by authorized installation personnel, and the works
must be carried out in accordance with the applicable law. The unit
must be disposed of and treated at special treatment facilities for
reuse, and recycling. By making sure that this product is properly
handled and disposed of, you help to minimize the negative impact
on the environment and human health. For more information, please
contact the installation personnel or local organization.
Use the system within the following temperature and humidity ranges
in order to operate it safely and effectively.
5 Operations
5.1 Operating Range
5.2 Operating System
5.2.1 About the system operations
5.2.2 About the cooling, heating, fan only and auto operations
Temperature
Mode
Outdoor
temperature
Indoor
temperature
Indoor room’s
relative humidity
Cooling mode -5°C ~ 48°C 17°C ~ 32°C below 80%
Heating mode -25°C ~ 24°C 15°C ~ 30°C
The temperature should below 55°C during transporing
The safety device will be triggered if the temperature or humidity
exceeds these conditions, and the air conditioner may not run.
Compared to the cooling operation, the heating operation takes a
longer time.
Need to perform the following operations to prevent the heating
capacity from dropping or prevent cold air from coming out of the
system.
Defrost Operation
In the heating operation, as the outdoor temperature decreases, frost
may be formed on the heat exchanger in the outdoor unit, making it
more difcult for the heat exchanger to heat up the air. The heating
capacity decreases, and a defrosting operation needs to be performed
on the system in order for the system to provide sufcient heat to the
indoor unit.
At this point, the indoor unit will show the defrost operation on the
display screen.
The indoor fan motor will automatically stop running so as to prevent
cold air from coming out of the indoor unit when the heating operation
starts. This process will take some time. This is not a malfunction.
Note
The operating program varies with different combinations of outdoor
unit and controller.
To protect this unit, please turn on the main power supply 12 hours
before you start to operate this unit.
If there is a power outage while the unit is running, the unit will
automatically restart its operation when the power supply resumes.
The indoor units in the air conditioner can be controlled separately,
but the indoor units in the same system cannot operate in the
heating and cooling modes at the same time.
When the cooling and heating modes conflict, the mode is
determined based on the setting of the "S5" mode switch of the
outdoor unit.
Automatic
priority mode
Automatic selection of heating or cooling priority is
based on the ambient temperature.
Heating
priority mode
Indoor units in the cooling or fan mode will stop
running, while indoor units in the heating mode will
run as usual.
Cooling
priority mode
When you select the cooling mode as the priority
mode, the heating operations in the indoor unit stops
running, while the cooling mode will operate as usual;
No.63 (VIP
indoor unit) +
voting priority
mode
If the indoor unit 63 has been set and is turned on,
the operating mode of unit 63 will be regarded as the
priority operating mode of the system. If the indoor
unit 63 has not been set or not turned on, the mode
adopted by most indoor units at the same time will be
the priority operating mode of the system.
In response to
heating mode
only
Indoor units with the heating mode will operate
normally, while indoor units in the cooling or fan
mode will display the "E0 conict".
In response to
cooling mode
only
Indoor units in the cooling and fan modes will operate
normally, while indoor units in the heating mode will
display the "E0 conict".
5.2.3 About the heating operation
5.2.4 Operating system
i
When there is a drop in the external temperature, the heating
capacity decreases. If this happens, please use another
heating equipment and unit at the same time. (Make sure
the room is well ventilated if you are using an equipment that
produces re.) Do not place any equipment that may produce a
re where the air outlets of the unit are or below the unit itself.
Once the unit starts, it takes some time for the room
temperature to rise, as the unit uses a hot air circulation system
to heat the room.
If the hot air rises to the ceiling, causing the ground area to
become cold, it is recommended that you use a circulating
device (to circulate the indoor air). Please contact the agent for
details.
1. Press the "switch" button on the controller.
Result: The running light turns on and the system starts to run.
2. Repeatedly press the mode selector on the controller to select the
required operation mode.
Stop
1. Press the "switch" button on the controller again.
Result: The running light is now off, and the system stopped
running.
Information
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kaysun Amazon V - K2F at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kaysun Amazon V - K2F in the language / languages: English as an attachment in your email.

The manual is 0.49 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kaysun Amazon V - K2F

Kaysun Amazon V - K2F User Manual - German - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info