(F ig . 1 ) (F ig . 2 ) (F ig . 3 ) (F ig. 4 )
(F ig . 5 )
Installation drain hose
NOTE
The drain hose must be arranged beneath the copper pipe.
The drain hose must not be hunched or bent.
Do not wrap the drain hose by pulling it.
When the drain hose must be through the house, it should be wrapped
by the special heat insulated materials.
The copper pipe and the drain hose must be wrapped by felt strip. Heat
insulated pad should be used in the place that the pipe contact the wall.
ROUTE OF PIPE
REFIT OF DRAIN HOSE
If pipe came out of the right side of the indoor unit, cut part 1 on
the unit;
If pipe came out of the lower-right side of the indoor unit, cut part
"2" on the unit;
If pipe came out of the left side of the indoor unit, cut part 3 on
the unit.
If the pipe comes out of the left side of the indoor unit, the drain
hose must be refitted, otherwise water leakage may occur.
Refit methods: Interchange the position of drain hose and drain
rubber bib, the right diagram is un-refit position.
Clearance is not allowed after refit, it would lead to water leak.
Liquid pipe
Gas pipe
Adiabatic
underlay
Felt
Drain hose
Drain hose
Drain rubber
bid
Installation indoor unit
Let the pipe go through the wall hole and attach the
indoor unit to the mounting plate. (Locate the rib of
indoor unit in the hole of the mounting plate.)
Indoor unit
Bottom
The rib of indoor unit
The mounting plate
ARRANGEMENT OF DRAIN HOSE
To eject the condensate water easily, the drain hose should be declined downward. The arrangement in
diagram2-5 is wrong.
50mm or less
from floor
dip hose in water
water
leak
air
standing
water
decline
downward
decline
downward
water
leak
drain hose
hose (ID 15cm)
PVC hard
If the drain hose connected with the indoor unit is short, it may
be extended by the hose in the accessory box.
When the drain hose must be through the house, it should be
wrapped by the special heat insulated materials.
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Kalorik ac 1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Kalorik ac 1 in the language / languages: English as an attachment in your email.

The manual is 1,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Kalorik ac 1

Kalorik ac 1 User Manual - Dutch - 23 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info