Trouble Shooting
Don’t repair or disassemble the unit by yourself, unsuitable repair may make the quality-protected
card in vain, and even cause damage to the user or his/her possession.
Trouble Reason Solution
No power supply Power-on and turn on the unit.
Water-full indicator illuminate Drain out the inner stored water
Timer function is active Cancel Timer function
The unit
doesn’t work
Room temperature too low or
too high?
Suggesting ambient temperature
between 7-40
In direct sunlight Draw the curtains
Windows or doors open, many
eople or a heat source in the p
room
Close windows and turn on another
air conditioner
Filter is very dirty Clean or change the air filter
Air inlet or air outlet is blocked Clear out the stemming
The unit
does not
seem to
perform.
Room temperature is lower
than setting temperature
Change the setting temperature
The unit
noise is high
The unit is not put on flat
place
Put the unit on flat and hard
place( reduce noise)
Compress
or doesn’t
work
Heat-exceeded protection
is active
Re-start the unit 3 minutes later
till the temperature low down.
The distance is too far.
Control panel hasn’t received
the signal from remote control.
Let the remote control near the
unit and make sure it aims at the
air-outlet grille
Remote
control
doesn’t work
The batteries run out. Change the batteries
E1 on LCD
Coil temperature is abnormal
check coil temperature sensor or relevant
circuit
E2 on LCD
Room temperature is abnormal
check room temperature sensor or relevant
circuit
E4 on LCD
Anti-freezing protection
Waiting for defrosting, function will recover
automatically
P2 on LCD
Water is full inside the machine
Drain out water from drain port at bottom
rear of the unit.
If the solutions above don’t function for the troubles, please contact with special service agent
for help.
13


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Just Fire AIRCO 12000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Just Fire AIRCO 12000 in the language / languages: English as an attachment in your email.

The manual is 1,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info