6 Troubleshooting
The indicator shows the operating condition of the module.
For information on troubleshooting the router or
smartphone, see the relevant manufacturer's
instructions.
ON/OFF
indicator
Possible cause Remedy
Constantly
OFF
Power supply
interrupted.
B Switch ON power supply.
Power supply unit
cable not connected to
module.
B Make connection.
Power supply unit
faulty.
B Replace power supply unit.
Constantly
red
When commissioning
or restoring factory
settings: Neither BUS
nor LAN connection
available.
B Disconnect module from
power supply.
B Make BUS and LAN
connections.
B Recommission module.
Otherwise: internal
fault
B Replace module.
Flashing
red
LAN cable not
connected.
B Make LAN connection.
Router is switched off.
B Switch router on
1)
.
DHCP is disabled. B Enable DHCP at router
1)
.
Manually set MAC filter
prevents IP address
being issued.
B Set MAC filter for the MAC
address printed on the
enclosure (Æ Fig. 10, [1],
page 33).
No IP address available
for the module.
B Check router configuration
1)
.
LAN cable faulty.
B Replace LAN cable.
Alternating
red and
green
BUS and LAN
connection separated
after commissioning.
B Disconnect module from
power supply.
B Make BUS and LAN
connections.
B Recommission module.
Table 4 Fault table
6 720 647 836-01.1o
Constantly
orange
LAN connection
established; no access
to Junkers server via
internet.
B Disconnect module from
power supply for 10 seconds
and recommission it.
-or-
B Establish internet
connection
1)
.
-or-
B If internet access for the
router is periodically blocked,
remove the timeout
1)
.
-or-
B Open ports 5222 and
5223
1)
.
Flashing
green
Heat source switched
off.
B Switch ON heat source.
Module not connected
to BUS system.
B Make BUS connection.
Maximum cable length
for BUS connection
exceeded.
B Make shorter BUS
connection.
Short circuit or cable
break in the BUS
connection.
B Check BUS connection and
repair if required.
Constantly
green
No faults. Standard operation.
1) See manufacturer's instructions.
Faults with effects on the App function are also shown on
the App (e.g. no connection with the XMPP server, no
connection with the MB LAN, incorrect password, ...).
ON/OFF
indicator
Possible cause Remedy
Table 4 Fault table
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Junkers MB LAN at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Junkers MB LAN in the language / languages: English, German, Dutch, French, Italian, Polish as an attachment in your email.

The manual is 1,27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Junkers MB LAN

Junkers MB LAN Installation Guide - German - 12 pages

Junkers MB LAN Manual - Dutch - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info