28350
161
Zoom out
Zoom in
Previous page
1/404
Next page
3-89
TEST MENU
1.
2.
0.
EXIT
3.
4.MAG CURRENT
5.PM
6.
7.
SELF CHECK
PANEL TEST
ARPATEST
ERROR LOGGING
SYSTEM INFO
OFF ON
OFF ON
PM
Operation of Performance monitor・・・・・・・・・・・・・・・・・・・・・・・・・
This function con be used only when the radar equipment is equipped with the NJU-63/64
Performance Monitor.
1 Method of Operation
In the case that the equipment is provided with radar interswitch, the interswitch
shall be set to the Master Radar mode.
1 Click TEST.
The MAIN Menu will appear.
2 Click "ON" radio button of
"5.PM".
“ON” in “5.PM” will be set and the radar will
automatically be set to RM, OFF CENTER
OFF, IR OFF, PROCESS OFF, TGT ENH
OFF, FUNCTION OFF and 24 NM range.
The PM pattern for checking the receiving
system will appear and the [PM] indicator
bar-graph will also be in the TEST Menu to
be used for checking the transmitted power.
1 Click EXIT .
The TEST Menu will be closed.
Note: All target acquisitions by ARPA functions will be cancelled.
The target acquisition cancelled when PM is ON will not be
recovered.
The radar image is suppressed to make the PM image easy to
see.
So, the test menu should be always closed after the PM has
been checked.
Procedures
Exit
161


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for JRC JMA9933SA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of JRC JMA9933SA in the language / languages: English as an attachment in your email.

The manual is 7,69 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info