467784
2
Zoom out
Zoom in
Previous page
1/100
Next page
2
1.0 Relationship to the
authorities
Installation of a fireplace must be carried out in compliance with
national laws and regulations. All local ordinances, including
those that refer to national and European standards, must be
complied with when products are installed.
The installation can only be put into use after it has been checked
by a qualified inspector.
Contact your local building authorities before installing a new
fireplace.
A product data plate of heat-resistant material is affixed to the
product. This contains information about identification and
documentation for the product.
2.0 Technical data
Material: Cast iron
Finish: Black paint
Fuel: Wood
Log length, max.: 30 cm
Flue outlet: Top, rear
Flue pipe dimension: Ø150 mm/min. 177 cm
2
cross
section
Outside air connection: Alu. flex - Ø 100 mm
Approx. weight:
- with cast-iron base: Approx. 168 kg
- with cast-iron pedestal: Approx. 161 kg
- with cast-iron leg: Approx. 159 kg
- with cast-iron base
and glass door: Approx. 170 kg
- with glass base: Approx. 163 kg
- with three legs Approx. 154 kg
Optional extras: Rotating set (Jøtul 363), glass
decoration - top/sides/front,
soap stone - top.
Wood store (Jøtul F 364).
Dimensions, distances: See fig. 1
Technical data according to EN 13240:
Nominal heat output: 5,5 kW
Flue gas mass flow: 5,9 g/s
Recommended chimney draught: 12 Pa
Efficiency: 73%@5,8 kW
CO emission (13% O
2
): 0.12%
Flue gas temperature: 330
o
C
Operational type: Intermittent
Intermittent combustion in this context means normal use of the
fireplace, i.e. fuel is added as soon as the fuel has burnt down to
a suitable amount of embers.
ENGLISH
Table of contents
1.0 Relationship to the authorities ................... 2
2.0 Technical data ..............................................2
3.0 Safety ............................................................ 3
4.0 Installation ..................................................8
5.0 Daily use ......................................................18
6.0 Maintenance .............................................. 19
7.0 Service ......................................................... 19
8.0 Operational problems -
troubleshooting .........................................20
9.0 Optional Equipment ..................................20
10.0 Warranty .....................................................20
On all our products there is a label
indicating the serial number and
year. Write this number in the
place indicated in the installation
instructions.
Always quote this serial number when
contacting your retailer or Jøtul.
les combustibles recommandés.
Respectez les consignes d'utilisation. Utilisez uniquement
Verwenden Sie nur empfohlenen Brennstoffen.
Montage- und Bedienungsanleitung beachten.
Follow user`s instructions. Use only recommended fuels.
standard
Certificate/
The appliance can be used in a shared flue.
Minimum distance to adjacent combustible materials:
Emission of CO in combustion products
Serial no: Y-xxxx, Year: 200x
Manufacturer:
N-1602 Fredrikstad
Norway
Jøtul AS
POB 1441
Sweden
EUR Intermittent
Nominal heat output
Norway
Country
Operational type
Fuel type
Operation range
Efficiency
Klasse II
Classification
Standard
Flue gas temperature
Room heater fired by solid fuel
Product:
Jøtul
SP Sveriges Provnings- och
221546
Forskningsinstitut AB
SP Swedish National
Testing and Research
Institute
:
Approved by
:
:
:
:
:
:
:
Minimum distance to adjacent combustible materials:
OGC
SP
EN
Serial no.
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jotul F 365 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jotul F 365 in the language / languages: English, Dutch, French, Italian, Spanish as an attachment in your email.

The manual is 1,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info