POWER CONNECTIONS
Before installing the amplifier, disconnect the
negative (ground) wire from the vessels battery.
This will prevent accidental damage to the system,
the vessel and your body during installation.
The M700/5’s +12 VDC and Ground
connections are designed to accept 4 AWG
power wire. 4 AWG is the required wire size for
this amplifier.
If you are installing the M700/5 with other
amplifiers and wish to use a single main power
wire, use 2 AWG or 1/0 AWG main power wire
(depending on the overall current demands of all
the amplifiers in the system). This large power
wire should terminate into a fused distribution
block mounted as close to the amplifiers as
possible (within 12 inches / 30cm of wire length).
The fused output of the distribution block will
connect to the M700/5 with 4 AWG power wire.
JL Audio ECS fused distribution blocks are
recommended (XD-FDBU-2 and XD-FDBU-4)
Note: Smaller AWG numbers mean bigger
wire and vice-versa (1/0 AWG is the largest, 2
AWG is smaller, then 4 AWG, then 8 AWG, etc.).
To connect the power wires to the amplifier,
first back out the set screw on the top of the
terminal block, using the supplied 2.5 mm hex
wrench. Strip 1/2 inch (12 mm) of insulation from
the end of each wire and insert the bare wire into
the terminal block, seating it firmly so that no
bare wire is exposed. While holding the wire in
place, tighten the set screw firmly, taking care not
to strip the head of the screw.
The ground connection should be made using
the same gauge wire as the power connection.
Any wires run through barriers must
be protected with a high quality rubber
grommet to prevent damage to the
insulation of the wire. Failure to do so
may result in a dangerous short circuit.
Many vessels employ small (10 AWG - 6 AWG)
wire to connect the alternator’s positive
connection to the battery. To prevent voltage
drops, this wire should be upgraded to 4 AWG
when installing amplifier systems with main
fuse ratings above 60A.
It is common for the alternator to be grounded
through its chassis. If the alternator is not
grounded through its chassis and instead employs
a small (10 AWG - 6 AWG) wire to connect to
ground, this wire should also be upgraded to 4
AWG when installing amplifier systems with main
fuse ratings above 60A.
FUSE REQUIREMENTS
It is absolutely vital that the main power
wire(s) to the amplifier(s) in the system be
fused within 18 inches (45 cm) of the positive
battery post connection. The fuse value at each
power wire should be high enough for all of the
equipment being run from that power wire. If
only the M700/5 is being run from that power
wire, we recommend a 60A fuse be used.
If fusing the amplifier near its power
connections (when more than one amp is being
run from the main power wire), use a 60A fuse.
MAXI™ plastic-body fuses are recommended.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for JL Audio M700 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of JL Audio M700 in the language / languages: English as an attachment in your email.

The manual is 1,48 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info