out of the preamp outputs of the amplifier are
compatible with the “Low” setting on the
“Input Range” control.
The “Signal Sensing” turn-on feature will not
work on “slave” amplifiers, but “slave” amplifiers
can be turned on and off by a “master” amplifier
operating in signal sensing turn-on mode.
Simply connect the “master” amplifier’s
“Remote” connection, to the “slave” amplifier(s)
“Remote” connection(s).
Do not increase the “Input Sens. setting for any
amplifier in the system beyond the maximum level
established during the procedure outlined in
Appendix B (page 14). Doing so will result in
audible distortion and possible speaker damage.
4) If you would like to run a third amplifier in
“Slave” configuration, select the “Full-Range”
position on the “Output Mode” switch of the first
“Slave” amplifier.Then, connect an RCA cable
from the first “Slave” amplifier’s preamp outputs to
the second “Slave” amplifier. As you did with the
first “Slave” amplifier, set the second “Slave”
amplifier’s “Amp LP Filter” to the “Off position.
Then, calibrate the third amplifier’s “Input Range”
and “Input Sens.controls in the same manner as
you did for the second amplifier.
Additional amplifiers may be added to this
“Master/Slave” configuration following the same
procedure as in step 4.
Once you match the input sensitivities of all the
amplifiers, you can use the “Master” amplifier’s
“Amp LP Filter” and “Advanced Bass Control”
features to control the “Slave” amplifier(s). If the
remote bass control (RBC-1) is used, it need only
be connected to the “Master” amplifier to control
all the amplifiers in the Master/Slave chain.
Below is a diagram showing a Master/Slave
configuration with one “Master” (top amplifier)
and two “Slave” amplifiers. Switches and controls
that are defeated in the “Slave” amplifiers are
printed in gray.
JL AUDIO 1000/1 17
Low/High
Low/High
Low/High
Connect Master 1000/1 Preamp Output to Slave A 1000/1 Input
Connect Slave A 1000/1 Preamp Output to Slave B 1000/1 Input
Connect Master 1000/1 Input to Signal Source
+12VDC Ground Remote
+12VDC Ground Remote
+12VDC Ground Remote
IMPORTANT
!
Set all amps in chain to "Normal" OR
Set all amps in chain to "Reversed"
Make sure that the "Output Polarity"
switches are in the same position for
all the amplifiers in a master/slave chain.
APPENDIX C:
Master/Slave Configurations
With the flexible on-board crossovers and
processing incorporated into the 1000/1, it is
possible to connect multiple 1000/1’s in a
“Master/Slave” configuration, with each amplifier
driving its own speaker system but controlled by
the processing and filtering of only one amplifier.
This is very useful when driving multiple
subwoofers with multiple amplifiers.
To create a Master/Slave configuration, first
determine which amplifier will be the “Master”
amplifier and connect the main input signal to that
amplifier (from the source unit or from an
outboard processor).This amplifier’s Amp LP
Filtersection and Advanced Bass Control
features will process the signal for the “Slave”
amplifier or amplifiers.
Here is the procedure for implementing a
“Master/Slave” configuration:
1) Set the “Master” amplifier’s Output Mode
switch to the center Amp Filter position.This will
send a parallel, mono-summed signal from the
“Master” amplifier’s Amp LP Filtersection to its
preamp outputs.
2) Connect an RCA cable from the “Master”
amplifier’s preamp outputs to the main input of the
first “Slave” amplifier. Set the “Slave” amplifier’s
Amp LP Filterto the Off position.This will
defeat the LP filter and the bass processing of this
“Slave Amplifier”.
3) The input sensitivity of the two amplifiers
needs to be adjusted independently.To properly
calibrate the amplifiers for maximum, identical, clean
output, please refer to Appendix B (page 14).
After using this procedure, you can then adjust the
level of the amplifiers by adjusting the input
sensitivities downward, if the amplifiers require
attenuation to achieve the desired system balance.
If the input sensitivities are adjusted, the amplifiers
must be recalibrated to ensure identical power
output levels.
Please note that the Input Rangeswitch on
all “slave” amplifiers needs to be set to Low,
even if the “master” amplifier is high voltage and
its switch is set to High. All signals passed
16 JL AUDIO 1000/1
The Master amplifiers
“Advanced Bass Control”
section is active and affects
all three amplifiers equally.
The last Slave amplifiers
“Advanced Bass Control”
section,AMP LP Filter and
“Preamp Output” are inactive.
This Slave amplifiers
“Advanced Bass Control”
section and AMP LP Filter are
inactive, but the Full-Range
(pass-through) feature of its
“Preamp Output” feeds the
input of the next Slave amplifier.
SLAVE (B):
MASTER:
SLAVE (A):
9


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for JL Audio 1000 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of JL Audio 1000 in the language / languages: English as an attachment in your email.

The manual is 0,39 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info