555024
2
Zoom out
Zoom in
Previous page
1/2
Next page
Setting buttons:
LEARN if this button is briefly pressed, you can scroll through the
learning modes of Z1-Z8 zones (a selected channel is
indicated by a red flashing LED).
RESET if this button is briefly pressed, the learning mode of a
selected zone will be closed. When this button is pressed for
more than 3 sec., a selected zone will be deleted (confirmed
by flashing of the TMP, BAT and TRB indicators). When this
button is pressed for more than 6 sec., all zones will be
deleted (confirmed by flashing of all indicators). Note, in
order to delete all zones, a learning mode of any zone must
be selected first.
UC-282 expanding module 2 / 2 MFT51804
Jumpers:
1s / 3s pulse length of 1 sec. or 3 sec. of Z1-Z8 output relays
NO / NC normally closed or normally opened mode of Z1-Z8 output
relays (TMP, BAT and TRB are normally closed)
Supervision - Regular checking of wireless detectors’ communication
can be disabled (NO SUPERVISION position). This setting
is recommended in places with radio interferences. When
the supervision is enabled, lost communication will trigger
the TRB output relay.
Indicators:
POWER The green LED indicates the presence of the power supply
Z1 - Z8, LED lights green when zone is occupied;
LED lights red when zone detector is triggered;
LED flashes red, when zone is in a learning mode;
LED flashes red together with the TMP, BAT or TRB LED =
tamper, low battery or trouble signal in zone
TMP tamper alarm – flashes together with a corresponding zone
indicator every 3 sec.
BAT low battery - flashes together with a corresponding zone
indicator every 3 sec.
TRB trouble or lost communication - flashes together with a
corresponding zone or SIR indicator every 3 sec.
Enrolling of wireless components
Enrolling of detectors
Scroll to a desired zone Z1-Z8 using the LEARN button
JA-60 detectors will be enrolled by inserting their batteries or
switching on a power supply
Successful learning is indicated by the red LED
If you enroll a component to a new zone, it will move from its
previous position
Only one detector can be enrolled to each zone
Enrolling of remote controls
Scroll to a desired zone Z1-Z8 using the LEARN button
RC-xx remote controls will be enrolled by pressing a button (while in
pulse mode). Button A, B or double press can be enrolled.
RC-11 or RC-22 Remote controls can be enrolled to any zone in an
ON/OFF mode by pressing both buttons and keeping them pressed
for more then 5 sec. After this the corresponding relay will switch on
when the A button is pressed, and off, when the B button is pressed.
If a combination of double press and ON/OFF mode is required, the
ON/OFF mode must be enrolled first.
Successful learning is indicated by the red LED
If you enroll a remote control to a new zone, it will move from its
previous position
Only one remote control can be enrolled to each zone
Erasing components
If you want to delete any item from a UC-282, use the RESET button
(the procedure is described in “Setting buttons” paragraph).
Extension for more zones
When 8-zone extension is not enough, you can use additional
UC-282 expanding modules. Up to 4 UC-282 can be used with one
UC-280 or UC-281. Modules are interconnected using the IN and OUT
connectors, wiring should not exceed 1 meter.
Internet: www.jablotron.cz
Tel.: +420 483 559 999
fax: +420 483 559 993
Po d Skalko u 3 3
466 01 Jablonec nad Nisou
Czech Republic
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron UC-282 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron UC-282 in the language / languages: English as an attachment in your email.

The manual is 0,08 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info