7. A remote control or doorbell button (RC-4x, RC-22,
RC-28) can be enrolled by pressing the button on the
controller. Multiple pressing of the controller’s button will
allow you to scroll to the desired melody.
8. Detector-chime mode: JA-60 detectors can be enrolled
by inserting batteries into them, one detector at a time. By
triggering the tamper on a detector you can scroll to the
desired melody.
9. Exit programming mode by briefly pressing the button
on the UC-261.
Note:
Up to 8 doorbell buttons or detectors can be used with one
UC-261.
If you enter programming mode the above way, all
previously enrolled devices will be erased from the
UC-261 memory.
Enrolling additional devices
If you want to add additional doorbell buttons or detectors, or
if you want to select another melody for an existing device, then:
1. Unplug the UC-261 from the outlet and wait for 5 seconds.
2. Plug it in again.
3. When the button lights – press it and hold it down. After
hearing a short beep, release the button. The flashing
button indicates that it is in programming mode.
4. Enrolling new devices (or selecting another melody):
A doorbell button or remote control (RC-4x, RC-22,
RC-28) can be enrolled by pressing the button on the
controller. Multiple pressing of the controller’s button will
allow you to scroll to the desired melody.
Detector-chime mode: JA-60 detectors can be enrolled
by inserting batteries into them, one detector at a time. By
triggering the tamper on a detector you can scroll to the
desired melody.
5. Exit programming mode by briefly pressing the button on
the UC-261.
Deleting enrolled devices
Press and hold the button on the UC-261 and plug the
UC-261 into the mains outlet. Two beeps will be heard and all
devices including the control panel will then be erased.
Consequently it is necessary to erase the UC-261 from the
control panel. In control panel enrollment mode scroll to the
UC-261 position, press and hold button 2 until the confirmation
beep can be heard.
Note: If the memory of the UC-261 is deleted but the UC-261 is
not erased from the control panel, then the control panel will
indicate disconnection of the UC-261 from the power but the
UC-261 will not react to signals from the control panel – in
the case of an alarm it will not sound.
Loudness selection
The UC-261 must be in its normal operating mode
(plugged in).
Press and hold the button down.
After 2 seconds you will hear a melody with the new
loudness selected
Release the button.
This way you can toggle between a standard and a quieter
level. This setting does not affect the alarm siren sound.
Power failure
If the UC-261 is disconnected from its power (it is
unplugged or there is a power failure), then a “Low battery”
report will be transmitted to the control panel. In addition if the
system is in alarm mode (the sirens are sounding) the UC-261
will also transmit a “TAMPER“signal.
Doorbell-mode
After pressing a doorbell button, the UC-261 will play a
preselected melody. Different melodies can be assigned to
each doorbell button, if desired. If you want to change a
melody, enter programming mode (see section “Enrolling
Additional Devices”) and press the button until the desired
melody is selected.
Detector-chime mode
If an enrolled detector is triggered, the UC-261 will play a
pre-selected melody. The melody can be changed if desired
(see section “Enrolling Additional Devices”).
A detector enrolled to the UC-261 can be simultaneously
enrolled to a JA-63 or JA-65 control panel. This way, for
example, a wireless door detector can activate a chime on the
UC-261 and at the same time trigger an alarm.
Notes:
1/ The JA-60P motion detector has a special sleep mode
feature (settable to 5 min. or 1 min.). Therefore it cannot detect
more frequent movements in a covered area.
2/ The JA-60SP, JA-60SR fire detectors and JA-60G
cannot be used for chime mode.
Wireless siren mode
The UC-261’s light indicator shows the status of the PgY
output of the enrolled control panel. If an alarm is triggered, the
UC-261 siren sounds. ARM and DISARM chirps can be
enabled or disabled by the following procedure:
1. Unplug the UC-261 from the outlet and wait for
5 seconds.
2. Plug it in again.
3. When the button lights – press it and hold it down.
After hearing a short beep, release the button. The
flashing button indicates that it is in programming mode.
4. On the control panel in P mode enter 299 repeatedly to
toggle between these two settings:
When one beep is heard, no chirps will be performed by
the UC-261.
When two beeps are heard, both ARM and DISARM
chirps will be performed by the UC-261.
Note: Although this product does not contain any
harmful materials we suggest you return the product to
the dealer or directly to the producer after use.
Internet: www.jablotron.cz
Tel.: +420 483 559 999
fax: +420 483 559 993
Pod Skalkou 33
466 01 Jablonec nad Nisou
Czech Republic
UC-261 wireless indoor siren 2 / 2 MFI52702
7. A remote control or doorbell button (RC-4x, RC-22,
RC-28) can be enrolled by pressing the button on the
controller. Multiple pressing of the controller’s button will
allow you to scroll to the desired melody.
8. Detector-chime mode: JA-60 detectors can be enrolled
by inserting batteries into them, one detector at a time. By
triggering the tamper on a detector you can scroll to the
desired melody.
9. Exit programming mode by briefly pressing the button
on the UC-261.
Note:
Up to 8 doorbell buttons or detectors can be used with one
UC-261.
If you enter programming mode the above way, all
previously enrolled devices will be erased from the
UC-261 memory.
Enrolling additional devices
If you want to add additional doorbell buttons or detectors, or
if you want to select another melody for an existing device, then:
1. Unplug the UC-261 from the outlet and wait for 5 seconds.
2. Plug it in again.
3. When the button lights – press it and hold it down. After
hearing a short beep, release the button. The flashing
button indicates that it is in programming mode.
4. Enrolling new devices (or selecting another melody):
A doorbell button or remote control (RC-4x, RC-22,
RC-28) can be enrolled by pressing the button on the
controller. Multiple pressing of the controller’s button will
allow you to scroll to the desired melody.
Detector-chime mode: JA-60 detectors can be enrolled
by inserting batteries into them, one detector at a time. By
triggering the tamper on a detector you can scroll to the
desired melody.
5. Exit programming mode by briefly pressing the button on
the UC-261.
Deleting enrolled devices
Press and hold the button on the UC-261 and plug the
UC-261 into the mains outlet. Two beeps will be heard and all
devices including the control panel will then be erased.
Consequently it is necessary to erase the UC-261 from the
control panel. In control panel enrollment mode scroll to the
UC-261 position, press and hold button 2 until the confirmation
beep can be heard.
Note: If the memory of the UC-261 is deleted but the UC-261 is
not erased from the control panel, then the control panel will
indicate disconnection of the UC-261 from the power but the
UC-261 will not react to signals from the control panel – in
the case of an alarm it will not sound.
Loudness selection
The UC-261 must be in its normal operating mode
(plugged in).
Press and hold the button down.
After 2 seconds you will hear a melody with the new
loudness selected
Release the button.
This way you can toggle between a standard and a quieter
level. This setting does not affect the alarm siren sound.
Power failure
If the UC-261 is disconnected from its power (it is
unplugged or there is a power failure), then a “Low battery”
report will be transmitted to the control panel. In addition if the
system is in alarm mode (the sirens are sounding) the UC-261
will also transmit a “TAMPER“signal.
Doorbell-mode
After pressing a doorbell button, the UC-261 will play a
preselected melody. Different melodies can be assigned to
each doorbell button, if desired. If you want to change a
melody, enter programming mode (see section “Enrolling
Additional Devices”) and press the button until the desired
melody is selected.
Detector-chime mode
If an enrolled detector is triggered, the UC-261 will play a
pre-selected melody. The melody can be changed if desired
(see section “Enrolling Additional Devices”).
A detector enrolled to the UC-261 can be simultaneously
enrolled to a JA-63 or JA-65 control panel. This way, for
example, a wireless door detector can activate a chime on the
UC-261 and at the same time trigger an alarm.
Notes:
1/ The JA-60P motion detector has a special sleep mode
feature (settable to 5 min. or 1 min.). Therefore it cannot detect
more frequent movements in a covered area.
2/ The JA-60SP, JA-60SR fire detectors and JA-60G
cannot be used for chime mode.
Wireless siren mode
The UC-261’s light indicator shows the status of the PgY
output of the enrolled control panel. If an alarm is triggered, the
UC-261 siren sounds. ARM and DISARM chirps can be
enabled or disabled by the following procedure:
1. Unplug the UC-261 from the outlet and wait for
5 seconds.
2. Plug it in again.
3. When the button lights – press it and hold it down.
After hearing a short beep, release the button. The
flashing button indicates that it is in programming mode.
4. On the control panel in P mode enter 299 repeatedly to
toggle between these two settings:
When one beep is heard, no chirps will be performed by
the UC-261.
When two beeps are heard, both ARM and DISARM
chirps will be performed by the UC-261.
Note: Although this product does not contain any
harmful materials we suggest you return the product to
the dealer or directly to the producer after use.
Internet: www.jablotron.cz
Tel.: +420 483 559 999
fax: +420 483 559 993
Pod Skalkou 33
466 01 Jablonec nad Nisou
Czech Republic
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron UC-261 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron UC-261 in the language / languages: English as an attachment in your email.

The manual is 0,26 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info