Operating of the remote control in this mode is as follows:
pressing button A while both UC-216 relays are off, the relay X will
be activated for 2 minutes
pressing button B while both UC-216 relays are off, the relay Y will
be activated for 2 minutes
pressing any remote control button while any UC-216 relay is on,
will switch off this relay.
Up to 20 remote controls can be enrolled to this mode, using the
method above. After the first remote control is enrolled to this special
mode, no other UC-216 learning mode will be available.
Use of the UC-216 with JA-60 detectors
All wireless JA-60 detectors can be
used with the UC-216. In such a case the
UC-216’s outputs have the following
functions:
relay X alarm trigger (detector output)
relay Y tamper output (tampering of a
detector or the signal that
a detector was lost) - all
detectors are supervised
OUT low battery signal from
a detector
A maximum of eight JA-60 detectors can be enrolled into a single UC-
216’s memory. The UC-216’s outputs will react to all enrolled detectors.
For example if any enrolled detector has an opened cover, the UC-
216’s Y relay will be activated.
The X relay reacts to all types of signals from a JA-60 detector (INST,
DELAY, FIRE, PANIC). For example, the selection of INST or DELAY
reaction in a JA-60P makes no difference to the function of the UC-
216’s output ( the relay will be activated instantly when any movement is
detected).
Enrolling of JA-60 detectors
Detectors can be enrolled to a UC-216 only if all other items (remote
controls) have been erased from the UC-216’s memory. The detectors
can be enrolled the following way:
remove the batteries from the JA-60 detector
select learning mode no. 1 for relay X in the UC-216
install batteries into the detector
the UC-216 will automatically store the detector’s code into its memory
close the cover of the JA-60 detector
By repeating this procedure you can teach up to eight JA-60 detectors
to each UC-216.
After the first JA-60 detector is enrolled, no other item will be possible
to enroll other than additional JA-60 detectors.
Use of the UC-216 with a JA-60D keypad
JA-60D keypads can be used with the
UC-216. In such a case the UC-216’s
outputs have the following functions:
relay X will change its status after a
valid access code is entered
on the keypad (on - off - on
...). The relay can also be
switched on by entering F1 on
the keypad (a quick arm
function).
relay Y is a tamper output (tampering of a keypad, more than 5
unsuccessful attempts to enter a valid access code or the
signal that the keypad was lost) - all keypads are
supervised
OUT low battery signal from a keypad
A maximum of eight JA-60D keypads can be enrolled into a single
UC-216’s memory. The UC-216’s outputs will react to all enrolled
keypads. For example if any enrolled keypad has an open cover, the
UC-216’s Y relay will activate.
Enrolling of the JA-60D keypad
The JA-60D keypads can be enrolled to a UC-216 only if all other
items (remote controls, detectors) have been erased from the UC-216’s
memory. The keypad can be enrolled the following way:
remove the battery from the JA-60D
select learning mode no. 1 for relay X in the UC-216
install the battery into the keypad
The UC-216 will automatically store the keypad’s code into its
memory
close the cover of the JA-60D keypad
By repeating this procedure you can teach up to eight JA-60D
keypads to each UC-216.
After the first JA-60D keypad is enrolled, no other item will be able to
be enrolled other than additional JA-60D keypads.
Supervising Detectors and Keypads
All enrolled JA-60 detectors (or keypads) transmit regular testing
signals. If the UC-216 does not receive this testing signal from any
enrolled detector (keypad) for a period longer than 1 hour, relay Y will
be triggered (tamper output).
This supervising function can be disabled by disconnecting the JP1
jumper in the UC-216.
Note: If the JP1 link is open, supervising is disabled and all of the UC-
216’s outputs (X, Y and OUT), will have a 2 second pulse reaction to
signals from detectors or keypads. In the contrary, when the JP1 is closed,
all of the UC-216’s outputs are copying the status of the detector (for
example, the Y relay is activated for the entire period in which a detector
or a keypad is open, etc.) and entering of the access code on the keypad
will change the condition of the relay X (on - off - on...).
Use of the UC-216 with the JA-60K control panel.
The UC-216 can also be used as a
wireless output module for the JA-60K
control panel. The UC-216's X and Y
output relays will have the same functions
as the PgX and PgY programmable
outputs of the control panel (see JA-60
installation manual for more details). The
OUT output will indicate if the JA-60
system has any problem with power (low
battery in items, failure of AC etc.).
To use the UC-216 with the control
panel, all other items have to be erased from the UC-216’s memory.
The control panel can be enrolled the following way:
enter the programming mode on the JA-60K
select learning mode no. 1 for relay X in the UC-216
enter the code 299 on the JA-60K keypad
The UC-216 will automatically store the control panel’s code in its
memory
exit the JA-60K’s programming mode
Up to eight JA-60K control panels can be enrolled to each UC-216.
After the first JA-60K is enrolled, no other item will be able to be
enrolled other than additional JA-60K control panels.
Erasing items from the UC-216’s memory
All enrolled remote controls (or JA-60 items) can be erased from the
UC-216’s memory. Open the cover and press both setting buttons and
hold them pressed until all indicators flash for a moment. The UC-216‘s
memory will now be erased.
Note: Although this product does not contain any harmful materials we suggest
you to return the product to the dealer or directly to the producer after usage.
fax: 420 483 559 993
tel.: 420 483 559 999
www.jablotron.cz
export@jablotron.cz
Po d Skalko u 3 3
466 01 Jablonec nad Nisou
Czech Republic
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron UC-216 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron UC-216 in the language / languages: English as an attachment in your email.

The manual is 0,05 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info