The TP-82 wireless thermostat 2 / 2 MKL51103
Locking the thermostat
To prevent the accidental changing of the set temperature the
thermostat can be locked by pressing and holding the knob (for
about 2 seconds, the lock symbol will appear on the display).
To unlock the thermostat simply press and hold the turning knob
(for about 2 seconds, the lock symbol will disappear on the display).
Integration into the OASIS system
The thermostat can also be enrolled to a control panel as a
detector. If the temperature decreases below ALLo a panic alarm
will be triggered = frost threat (heating failure).
If the temperature exceeds ALHi then a fire alarm will be triggered.
An AC-82 receiving unit has two output relays (X and Y). TP-82
thermostats can be enrolled separately to each relay (in enrollment
mode 4) in order to control two independent heating circuits.
To operate a heating system the Oasis control panel can also
be enrolled (sequence 299) to the same relay as the thermostat is
enrolled to. A thermostat enrolled to the X relay can be operated
via the PGX programmable output, and a thermostat enrolled to
the Y relay operated via PGY. If the programmable output of the
control panel is switched on, the thermostat maintains the set
temperature. If the control panel’s output is switched off the
thermostat only triggers heating if the temperature drops below
InLo (anti-freeze protection).
To operate the heating, RC-80 or RC-88 remote controls can
also be enrolled to a receiving unit (AC-82). The heating can be
switched on by remote controls to heat to the desired temperature
and also switched off where it only heats when the temperature
is below ALLo.
To disable heating when windows are open JA-80M or JA-82M
detectors can also be enrolled to the same relay as the thermostat
is enrolled to. If the windows are closed it heats to the desired
temperature and if windows are open it heats only when
temperature is below ALLo.
Up to 8 thermostats can be enrolled to a single relay. If at least
one thermostat transmits a heat command then the relay will be
switched on.
Battery replacement
Replace the battery when the low-battery symbol is displayed (or the
thermostat stops working). If the thermostat is enrolled to the control
panel, then a low battery will be indicated by the control panel (to the
user and installer). Use only AA 1.5V alkaline batteries.
RESET
The RESET function allows you to reset the device to factory defaults
listed in the table. You can perform RESET by selecting Res in the
adjustment menu and pressing and holding the knob for 5 seconds.
Specification
Power supply: 1x AA 1.5 V alkaline battery
Battery lifetime typically 1 year
Temperature measurement: +6°C to +40 ˚C
Temperature accuracy: adjustable: ± 0.1, ± 0.2 or ± 0.5 ˚C
Freeze alarm (panic transmission) temperature threshold: <ALLo
configurable from –9°C to +20°C
Fire alarm temperature threshold: >ALHi
configurable from 30°C to 70°C
Operational frequency: 868 MHz, Oasis protocol
Operational radio range: up to 100 m (open area)
Operational temperature range: -10°C to + 70°C (low humidity)
Dimensions: 65 x 88 x 20 mm
Can be operated according to VO-R/10/05.2006-22
Jablotron Ltd. hereby declares that the TP-82 is in
compliance with the essential requirements and other
relevant provisions of Directive 1999/5/ES. The original of
the conformity assessment can be found on the web site
www.jablotron.com
, Technical Support section.
Note: Dispose of batteries safely depending on battery type
and local regulations. Although this product does not contain
any harmful materials we suggest you return the product to
the dealer or directly to the manufacturer after use.
20
65
32.5 32.5
88
25
44
19
Internet: www.jablotron.com
Tel.: 483 559 911
fax: 483 559 993
Pod Skalkou 33
466 01 Jablonec nad Nisou
Czech Republic
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron TP-82 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron TP-82 in the language / languages: English as an attachment in your email.

The manual is 0,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info