RC-60 Remote Control
The RC-60 is a wireless transmitter designed to control Jablotron
control panels via 3rd party wired access control devices (e.g.
proximity cad readers, mechanical locks with switches etc.). The RC-60
converts control signals from these devices into the wireless control
signals accepted by the JA-60, JA-63 and JA-65 control panels.
Additionally, it can be used to trigger UC-2xx receivers for various
home automation applications.
There are two input terminals (A & B) as well as a tamper input. The
tamper signal is transmitted if the RC-60 is opened or removed from the
wall.
The battery status of the RC-60 is checked automatically.
RC-60 Remote Control 2 / 2 MGW51006
Specification
Power supply 2 AAA alkaline batteries
Battery lifetime approx. 1 year
Frequency 433.92 MHz
RF Power
<
10 mW
Coding digital floating code
Operating range up to 100 m (open area)
Inputs A and B triggered by switching to GND
TMP tamper input must be connected to GND
Input wires length max 0.5 m
Environment class II, general interior (-10 to +40 °C)
Can be operated according to ERC REC 70-03
Complies with ETSI EN 300 220, ETS 300 683, EN 60950
Hereby, Jablotron Ltd., declares that this RC-60 is in compliance
with the essential requirements and other relevant provisions of
Directive 1999/5/EC.
Original of the conformity assessment can be found at the web page
www.jablotron.cz, section Technical support.
Installation
Open the cover by pressing in the tab on the bottom side of the detector.
Electronics and batteries are located inside the front cover.
Attach the bottom part to the wall or the frame of the door or window
using the provided screws.
Be sure that the antenna is vertical (pointing up or down).
Triggering
inputs
Tamper
input
Example of connection
Terminals
There are 4 input terminals:
TMP – when disconnected from the GND terminal it triggers the tamper
signal transmission (similar to opening the cover). If you do not use this
terminal, keep it connected to the GND.
A – when connected to the GND, the input A is triggered. If the MODE
jumper is closed, the ARM instruction will be transmitted.
B – when connected to the GND, the input B is triggered. If the MODE
jumper is closed, the DISARM instruction will be transmitted.
GND – ground terminal
Note:
The triggering wires should not be longer then 0.5 m. It is
recommended to use twisted pairs or screened cables.
Both mechanical and electronic switches can be used to trigger the A
& B inputs.
Enrolling the remote control
Read carefully the installation manual of the receiver. The JA-60, JA-63
and JA-65 control panels must be set to the enrolling mode. The detector
will generate an enrollment signal after the batteries are installed.
The procedure for enrolling into a UC-2xx is usually the same or an input
must be triggered (see a corresponding manual).
Operating
The MODE jumper enables the setting of the following modes:
MODE jumper is closed – the basic mode:
Temporary or permanent connection of the A input to the GND
causes ARM signal transmission. Disconnecting from the GND has
no effect.
Temporary or permanent connection of the B input to the GND
causes DISARM signal transmission. Disconnecting from the GND
has no effect.
This mode is suitable for arming and disarming control panels or for
UC-2xx triggering.
MODE jumper is open - the status and pulse mode:
Connecting the A input to the GND triggers the ARM signal.
Disconnecting it from the GND triggers the DISARM signal. This
means that the A terminal converts its status into controlling signals.
Temporary or permanent connection of the B input to the GND
causes PANIC signal transmission. Disconnecting from the GND
has no effect.
Note:
All triggering signals must be longer then 100 ms.
The MODE jumper status changes are in effect only after closing the
cover.
Battery replacement
The RC-60 automatically checks the condition of its batteries. If it is
necessary to replace the batteries, the RC-60 will inform the system. If a low
battery is indicated, it should be replaced as soon as possible.
Before the batteries are replaced, the receiver (control panel) must be put
into the mode, which allows for the opening of the remote control. Use only
high quality alkaline AAA batteries for replacement.
Note: Dispose of batteries safely depending on the type of the batteries
and local regulation. Even though this product does not contain any
harmful materials we suggest you to return the product to the dealer or
directly to the producer after usage.
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron RC-60 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron RC-60 in the language / languages: English as an attachment in your email.

The manual is 0,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info