JS-20 LARGO,P.I.R. detector MGD51205
JS-20 „LARGO“ P.I.R. detector
This P.I.R. motion detector is
used to protect interiors. It detects
any movement of objects with a
temperature close to that of the
human body.
The signal from the sensor is
electronically analyzed. This ensures
that the detector provides excellent
sensitivity and at the same time false
alarms are basically eliminated. The
detection analysis rate can be
adjusted to increase its immunity if
the JS-20 is installed in a
problematic location.
The standard lens in the detector
can be replaced with an optional
corridor or pet immune lens. Extra
terminals (GBS) can be used to
facilitate wiring of the detector.
The JS-20 distinguishes itself
with excellent RF immunity.
It can be mounted on a flat wall
or in a corner.
Installation
This detector is designed for
indoor applications. It can be mounted on a flat wall or in a corner. Do not
place the detector close to any heating/cooling vents or near any other object
that often change temperature. The detector must have an unobstructed view
of the protected area.
1. Open the cover of the detector (press in the plastic tab on the bottom
part of the detector’s housing with a screwdriver).
2. Remove the PCB by pressing the flexible tab inside the housing.
3. Punch through the pre-formed holes for cables and screws.
4. Attach the housing to the wall (2.5 meters above the floor).
5. Return the PCB into the rear housing and connect the cable wires to
the terminals.
6. Attach the cover.
Note: Avoiding touching or scratching the PIR sensor!
Terminals
+12V, GND power supply
PIR, PIR PIR alarm output (normally closed)
TMP, TMP TAMPER output (normally closed)
GBS, GBS auxiliary terminals – useful when wiring (see examples)
Jumpers
LED the LED indicator can be disabled by opening this jumper
DETECTION by opening this jumper you can set a higher rate of analysis
and increase the immunity of the detector. This setting is
suitable for problematic locations with sudden temperatures
changes or electromagnetic interference. Reaction of the
detector will be slightly slower in this setting.
Detector testing
After switching on the power, wait for 1 minute. During this period the
detector initializes and stabilizes its parameters (LED will be on if not
disabled).
Each detected movement will be indicated by the detector’s LED (if not
disabled)
Confirm that the detector covers the protected area as you expected.
Lenses
Standard lens that is supplied with the JS-20 Largo detector covers an
area of 120 degrees / 12 meters.
For special applications other lenses can be used. Optional lenses for long
corridors and areas with small animals are supplied separately.
The Pet lens is marked JS-7910. This lens prevents animals smaller then
40 cm to be detected by the detector. The working range of this lens is
reduced to 7 meters. It is recommended to test this lens carefully with the
animal when installing the system, in order to prevent false alarms.
The Corridor lens is marked JS-7904. The working range of this lens is
25 meters long and only 3 meters wide. It is recommended to test the
detector’s sensitivity carefully when installing it into a corridor.
The curtain lens is marked JS-7902. By using this lens the PIR detector's
working range is restricted to a "curtain". After using this lens, it is for
example possible to secure part of a room etc. During the installation it is
necessary to test the working range very carefully.
Lens characteristic diagrams can be seen in documents supplied with
the lens or on the Jablotron website www.jablotron.com .
Note: Although this product does not contain any harmful materials we
suggest you to return the product to the dealer or directly to the producer
after usage.
Specification
Power supply: 12 V DC ± 25%
Power consumption (LED off): max. 10 mA
Maximum consumption (LED on): max. 35 mA
Terminals size: max. 1 mm
2
Mounting height: 2.5 m above floor
Detection range: 120° / 12 m (standard lens)
Initialization: aprox. 1 minute
Alarm output: normally closed, max. 60V / 50 mA,
internal resistance max.30 Ohm
Tamper output: normally closed, max. 60 V / 50 mA,
internal resistance max.16 Ohm
Environment - class II. – general indoor, (EN 50131-1)
Operating temperatures -10 to +40 °C
Security level grade 2, EN 50131-1, EN 50131-2-2
EMC EN 50130-4, EN 55022
JABLOTRON ALARMS a.s. hereby declares that the JS-20 is in
compliance with the essential requirements and other relevant
provisions of Directive 2004/108/EC. The original of the conformity
assessment can be found on the web site www.jablotron.com
,
Technical Support section.
Note: Although this product does not contain any harmful materials
we suggest you return the product to the dealer or directly to the
manufacturer after use.
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron JS-20 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron JS-20 in the language / languages: English as an attachment in your email.

The manual is 0,57 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info