JA-68 universal output module 2 / 2 MGK23701
The JA-68 universal output module
The JA-68 is a universal output module designed for use within Jablotron
systems of the JA-80 OASiS, JA-63 Profi and JA-65 Maestro series. The
module provides eight factory pre-programmed semiconductor outputs and a
switch-over relay output. The relay can be configured using 10 DIP switches
which allows for multiple function assignment. There is no limit in the number
of JA-68 modules used in the system. There is no limit to the number of
JA-68 modules used in the system and the JA-68 module can be combined
with GSM, LAN or PSTN (landline) communicators.
The module is designed for being placed into the control panel
housing.
NC
C
NO
Figure 1
Semiconductor outputs
All semiconductor outputs are switchable to a common terminal labelled
“C”. The switching ON/OFF logic can be reversed by setting a jumper JP1 to
the NC position (the factory default is NO).
Description of the terminals:
Terminal Function
+U Positive power supply from the digital bus (limited to 200 mA)
GND Negative pole of the power supply
C Common terminal (for all semiconductor outputs)
ARM Anything-set status (A or AB or ABC)
ALM Intruder alarm
FIR Fire alarm
TMP Tamper alarm
PNC Panic alarm
FLT Fault indication (general faults, radio communication faults,
back-up battery supply faults)
AC Mains (230V) supply fault
LB Low battery indication (applies to wireless devices such as
detectors, keypads, sirens or thermostats)
Relay configuration
The relay is configurable via a set of 10 DIP switches (see Table 2). The
relay works with OR logic: it is switched ON if there is at least one preset
function activated.
Example: Setting switches 2,3,4 and 5 to ON causes the relay to
indicate intrusion, fire, tamper or panic alarms i.e. the relay switches ON if
any of the four mentioned alarm states are activated.
DIP switches assignments:
Number Label Function
1 ARM Anything set
2 ALM Intrusion alarm
3 FIR Fire alarm
4 TMP Tamper alarm
5 PNC Panic alarm
6 FLT System fault
7 AC Power supply fault
8 LB Low battery
9 PGX Control panel PGX output
10 PGY Control panel PGY output
Description of relay terminals:
Label Description
NC Normally Closed relay contact
C Common relay contact
NO Normally Open relay contact
Note: There is a minimum output activation time of 10 seconds for each
of the 8 + 1 outputs.
Specification
Power supply 12V (taken from the control panel)
Stand-by consumption 4mA
Maximum consumption (all outputs activated) 50mA
Outputs 8 semiconductor switches
+ 1 switch-over relay
Maximum current for single output activation 200mA
Maximum current for C, NC or NO activation 1A / 60V
Minimum output activation time 10 sec.
Digital bus connection 2x RJ-44 data connectors
Environment indoor general
Operational temperature range –10 to +40 °C
Complies with EN 50130-4,EN 55022
JABLOTRON ALARMS a.s. hereby declares that the JA-68
is in compliance with the essential requirements and other
relevant provisions of Directive 2004/108/EC. The original of
the conformity assessment can be found on the web site
www.jablotron.com, Technical Support section.
Note: Although this product does not contain any harmful
materials we suggest you return the product to the dealer or
directly to the manufacturer after use.


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron JA-68 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron JA-68 in the language / languages: English as an attachment in your email.

The manual is 0,07 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info