554902
1
Zoom out
Zoom in
The JA-63E wired keypad 2 / 2 MKP51001
The JA-63E digital bus wired keypad
The JA-63E keypad is designed to control and program alarm systems of
Jablotron’s JA-6x series. The keypad is equipped with backlit keys, built-in LED
signalling, acoustic signalling, and a display. It conveys information about the
system status in a convenient way. The keypad communicates via the control
panel digital bus. You can connect the keypad to the control panel via an RJ
cable or via a standard communication cable connected to terminals. Multiple
JA-63E keypads can be connected to a single control panel.
Any undesirable mishandling of the keypad (like opening its housing or tea-
ring the keypad off its position) will trigger tamper signalling. In addition, the
number of attempts to enter an access code is checked not to exceed a given
limit.
Installation
Select the desired keypad location close to the building’s entrance.
1. Open the keypad’s rear housing (by pressing the two tabs on the left or
right side).
2. Route all required cables through the hole in the rear housing and install
the housing to the desired location.
3. Connect the digital bus cable either to the terminal board or to an RJ
connector.
4. Close the keypad’s housing (attach the front housing on one side and
push it on the other side).
5. Switching on the control panel power makes the keypad ready for op-
eration.
Tabs
Tabs
SYSTEM 6 0
Installation notes:
Multiple JA-63E keypads in the system must be wired in parallel. Inlet
cables can be split directly in the control panel, in a converter, in the keypad or
in a junction box. RJ cable connection and connection to terminals can be
used in combination.
A connecting cable must be wired so that the corresponding positions
(terminals) are connected. When you use a self-made RJ cable, be careful to
connect identically coloured wire ends to identically marked positions (termi-
nals).
If the keypad does not function after being connected, disconnect the
inlet cable and check if the corresponding positions (terminals) in the control
panel and the keypad are connected.
Operation
The keypad can operate and program the system to the full extent as it is
described in the control panel manual.
The following table describes the meaning of symbols on the keypad LED
indicators:
Alarm
Power supply
Tamper
Set (Armed)
Fault
Battery
Wireless communication indication
Functions F1 through F0 can be used as described in the control panel ma-
nual. Besides this, there are 4 extra keys with the following functions:
Setting (Arm-
ing)
(equal to F1
entry)
Door opening
(equal to F3 entry)
Partial setting
(equal to F2
entry)
Panic (access under
duress)
(equal to F7, before
access code entry)
Remote system access
The JA-63E keypad allows you to remotely operate or program a JA-6x
system via a phone line using a JA-60U modem. Such operation requires the
system to be equipped with a telephone communicator with the remote access
feature enabled (see the security system installation manual).
Note: Remote system access via the JA-63E keypad is only possible using a
JA-60U modem of DY62012 version or higher.
Connecting remotely to the system: Connect the JA-60U modem to the
phone line. Connect the JA-63E keypad cable to the modem’s data connector.
After powering up the modem, the keypad will show a u on the display to
indicate that it is ready to establish a connection.
The initial connection is established by keying in:
xxxxxxxx F1 y F2 ttt...t F3 nnn...n F d
where:
xxxxxxxx is an 8-digit access code for system remote access
y answering machine bypass (a so-called second call) 0-
not bypassed, 1-bypassed
ttt...t call back tel. number – if call back is not requested just
enter F3 after F2
nnn...n the remote system tel. number (a pause can be specified
by keying in F0)
d dialling method: 4-tone, 5-pulse
After the d parameter is entered, the modem will establish a connection
and the keypad will display the remote system status. The keypad then beha-
ves the same way as if it had been connected directly to the system. Depen-
ding on the quality, the telephone line might be slower in its response. A JA-
63 remote connection disables the 4 big keys on the keypad’s right side. Use
keys F0 to F9 instead.
The connection is terminated by pressing key .
A re-connection (using the same modem) is established by entering F6. The
connection parameters are memorized.
If you perform a call to a control panel which has the same access code
but a different telephone number, you do not need to re-enter the whole con-
necting sequence. Instead, it is sufficient to key in nnn...n F4 – i.e. the control
panel tel. number followed by one of the F4/F5 keys (depending on the
tone/pulse dialling method).
Technical specifications
Connection with a cable to the JA-6x digital bus connector
Connecting cable 4 core cable with RJ connectors (4/4 1:1) or
ordinary telephone cable (terminals)
Length of the inlet cable max. 100 m when a paired cable is used
Power supply 10 –14 V (taken from the digital bus)
Power consumption 25mA
Enclosure IP40
Dimensions 125 x 145 x 30 mm
Complies with EN 50131-1, EN 50131-3 grade 2
Environmental class II indoor general -10 to +40°C
EMC EN 50130-4,EN 55022
Contents of the kit: JA-63E keypad, 4 m of connecting cable,
4 rawl plugs, 4 screws, 2 RJ-44 connectors.
Accessories – for keypad connection (can be ordered separately):
RJ-40 converter from RJ connector to 4 terminals
RJ-21 RJ connector splitter (2/1)
RJ-44 cable connector (4P/4C)
RJ-00 crimping tool for RJ connectors
CT-04 cable for RJ connectors
JABLOTRON ALARMS a.s hereby declares that the JA-63E is in compliance
with the essential requirements and other relevant provisions of Directive
2004/108/EC. The original of the conformity assessment can be found at
www.jablotron.com
, Technical Support section.
Note: Although this product does not
contain any harmful materials we
suggest you return the product to the
dealer or directly to the producer after
use. See www.jablotron.com for details.


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron JA-63E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron JA-63E in the language / languages: English as an attachment in your email.

The manual is 0,16 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info