GC-61 GSM communicator 3 / 3 MHZ51105
3. Web server remote access
3.1. Settings via the GSMLink web server
The GSMLink server allows a user to read and change the control
panel and dialler configurations. Data transfer is done by sending an
SMS or by GRPS.
The number of SMSes sent is optimised to minimize costs. GPRS
data transfer can also be used, but must be activated on the SIM card.
3.2. GSMLink Website Registration
The www.gsmlink.cz website: To register your system use the
registration code printed on the warranty certificate (the code has the
form xxxx-xxxxx-xxxx and it is unique to each system).
You can ask for the registration code by using the DINFO SMS
command. After sending the SMS from your mobile phone: (remote
access code) DINFO “0000 DINFO”, you will receive an SMS reply
with the registration code and the level of the GSM signal.
4. User features of the GSM communicator
The GC-61 can be also used as a GSM network gateway. It cannot
be used as an ARC communicator in this mode. The 10k resistor must
be removed from PHONE terminals.
4.1. Phone calls from the attached telephone set
After the GSM module is connected to the GSM network, an attached
phone can be used to make calls. If you pick up the phone, you will
hear a dial tone. Simply dial the number you want to call (as if you are
dialling from a normal fixed line phone). You can also dial the GSM
communicator’s phone number from another phone, and its attached
phone will ring as a normal land line phone would.
Note: some telephone sets are sensitive to the GSM radio signal. For
this reason you may hear a buzzing noise in the telephone receiver
when calling. If the noise is disturbing, change the location of the
phone set (try to keep it as far as possible from the GSM dialler
antenna). Usually it is possible to find a suitable location for the phone
with a minimum level of interference.
4.2. Function of the attached SMS terminal
The communicator has a telephone connector, which can be used for
connection to an MT-77 Piccolo terminal. A detailed description is in
the separate manual enclosed with the Piccolo terminal.
Setting:
For sending SMSes to mobile phones it is necessary to set the
SMS centre 1 to “1111”.
By sending SMSes to telephone number “001”, the control panel
can be controlled using SMS instructions
Notes:
When displaying the caller’s telephone number (CLIP), the telephone
number is shown in international format (e.g.00420212345678).
5. Additional information
5.1. Procedure for report data transfer:
If the communicator is activated to send reports it will:
Send information to ARC1 (to the primary number, if it fails the
backup number will be used); this process is repeated twice.
Send information to ARC2
If communication with the ARC is unsuccessful, the communicator
will try to send it again after a pause set by sequence PG7. The
GC-61 has a memory for 128 events.
5.2. LED indicator
If the LED is flashing, the dialler is not registered to the GSM
network
If the LED is flashing in short bursts:
Once in 2 seconds =normal status
Twice in 2 seconds = the balance resistor has not been detected
If the LED is on – communication with a GSM network is occurring.
5.3. ARC communication
If the GC-61 is being used for the first time or any parameters have
been changed then the first successful communication with an ARC
will result in a short ring on the connected telephone set (if there is
one).
When the GC-61 receives 10 report codes from the control panel then
the GC-61 will suspend communication with the control panel and the
received report codes will be sent to an ARC.
The command MO can be
used to read the current status of the GSM dialler. The dialler will reply
with an SMS showing the level of GSM signal, GPRS status, and
whether data transfer to ARCs is successful or not.
Example: After sending the MO instruction, the communicator will reply
with the SMS: Alarm system reports: Control panel status:
GSM:7,GPRS OK,MS1 NOT,MS2 OK
5.4. Setting SMS
When an SMS command has been processed correctly, the GC-61
sends back a confirmation SMS e.g.:
„ Settings stored: PG11 123456789“
Or in the case of error:
„ Wrong settings“
5.5. Telephone line supervision
When a 10 k resistor is attached to the PHONE terminals, the
telephone line is balanced. When the balancing resistor is connected
to the control panel, the connection between the GC-61 and the control
panel is supervised. If the telephone line is disconnected for 30 s, the
GC-61 will send a report to an ARC.
6. Specification
Power supply 12V DC
Stand-by consumption 50 mA
Maximum consumption (during communication) 1 A
Operating bands E-GSM / GPRS 900/1800MHz
Output power 2 W for GSM900, 1 W for GSM1800
AUX terminals dry contact, max. 60 V / 100 mA
Environmental classification ( –10 to 40°C) II
EMC ETSI EN 301489-1, ETSI EN 301489-7
EN 55022, EN 5030-4
Emissions ETSI EN 301419-1 and EN 301511
Caller identification (CLIP) ETSI EN 300 089 V3.1.1(2000-12)
Jablotron Ltd. hereby declares that the GC-61 is in
compliance with the essential requirements and other
relevant provisions of Directive 1999/5/EC. The original of
the conformity assessment can be found on the web site
www.jablotron.com, Technical Support section.
Note: Dispose of batteries safely depending on battery type
and local regulations. Although this product does not contain
any harmful materials we suggest you return the product to
the dealer or directly to the manufacturer after use.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron GC-61 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron GC-61 in the language / languages: English as an attachment in your email.

The manual is 0,17 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info