554983
2
Zoom out
Zoom in
Previous page
1/2
Next page
CR-11A Expander Module 2/4 MEI51205 CR-11A Expander Module 3/4 MEI51205
mode
no.
DIP switch
settings
Function of relay no. 1 Function of relay no. 2
1
1 sec. pulse after simultaneous
pressing of A&B buttons on the remote
control, when car alarm
is armed
1 sec. pulse after simultaneous
pressing of A&B buttons on the remote
control, when car alarm is disarmed
2
relay will change status after
simultaneous pressing of A&B
on RC, when car alarm is armed /*
relay will change status after
simultaneous pressing of A&B,
on RC, when car alarm is disarmed /*
3
left flasher output signals
(arming, disarming, alarm)
right flasher output signals
(arming, disarming, alarm)
4
lock (pulse duration selectable in the car
alarm setting mode)
unlock (pulse duration selectable in the
car alarm setting mode)
5
immobilization (relay switches ON when
car alarm is disarmed and the ignition
key is ON)
alarm (relay switched ON during
alarm condition)
6
immobilization (relay switches ON when
car alarm is disarmed and the ignition
key is ON)
arming signals (1 pulse = arming,
2 pulses = disarming)
7
courtesy (Dome) light control (relay
follows door switches + 1 minute) /**
arming signals (1 pulse = arming,
2 pulses = disarming)
8
immobilization (relay switches ON when
car alarm is disarmed and the ignition
key is ON)
courtesy (Dome) light control
(relay follows door switches + 1 minute)
/**
9
double locking impulse – during
arming relay will be switched ON for
0.3s, then switched OFF for 1s and
switched ON for 0.3s again
double unlocking impulse – during
disarming relay will be switched ON for
0.3s, then switched OFF for 1s and
switched ON for 0.3s again
10
Second locking impulse 1s after
preset locking car alarm impulse, relay
will be switched ON for 0.5s
Second unlocking impulse – 1s after
preset unlocking car alarm impulse, relay
will be switched ON for 0.5s
11
controlling of relay via SMS – only for
CA-180x, see CA-180x manual for more
details
controlling of relay via SMS – only for
CA-180x, see CA-180x manual for more
details
/* with each simultaneous press of the A&B buttons, the relay will toggle status (on - off - on ...). The relay will
also switch off for 15 minutes or after arming or disarming
/** the courtesy (Dome) light is on while a door is open (max. 15 minutes) and it will remain on until you
switch on the ignition key (max. 1 minute)
Examples of use
1. Trunk (boot) release by simultaneous pressing of A&B buttons on the remote control
Select mode no. 1 on the CR-11A module and disable the Panic alarm in the car alarm settings (if this
feature is supported). Opening the trunk (boot) by remote control is only possible when the car alarm is
disarmed.
2. Additional immobilization and an additional siren
Select mode number 5 on the CR-11A module. The additional immobilization provides a higher security
level, because it is impossible to bypass it even when somebody is tampering directly with the wire harness
of the car alarm unit (the CR-11A is waiting for digital data from the car alarm). The additional siren sounds
during the alarm period (the car horn can also be used as an additional siren).
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron CR-11A at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron CR-11A in the language / languages: English as an attachment in your email.

The manual is 0,23 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info