GSM car alarm CA-1803BT „Athos 1/6 MHF58202
Installation manual: CA-1803BT “Athos”
Before installation
This is the basic version of the installation manual and programming sequences.On
the web site www.jablotronalarms.com in the download section you can find a full
version of this manual or you can find it included in the installation kit on CD / DVD. If
you have no experience with CA-1803 installation, we recommend you to read
the extended version of the manual to know all the parameters well.
The immobilizer relay contact of car alarm is connected only in disarmed
mode and if the ignition is on. Do not block circuits that are under voltage
while the ignition is off. It could cause a serious damage of the vehicle.
The car alarm should only be installed by a professional installer. It is suitable for
cars with a dashboard voltage supply of 12V or 24V with a negative ground
connection. During the first power-up, the value of supply voltage is read and the
inputs are set to default settings. The alarm is designed to be installed inside the car.
For cars with a voltage supply of 24V, the following restrictions apply to
car alarm installation:
1. It is not possible to connect a hands-free set of type HF-03.
2. When used for acoustic signalling, the SIR output is switched to the power supply
voltage. Consequently, this output switches to 24V, so it is necessary to use a
siren of type SA-606-24V instead of the SA-530 which is supplied in the standard
package. In this case it is necessary to set the confirmation beeps to 100 ms.
Configuration table
SIM entry* SMS instruction Text Description
RESET EN 1
(After which, the
entry is erased
from the SIM)
MASTER RESET EN 1 Mode setting. RESET 1 = alarm has its own remote control and provides signals for central locking.
RESET 2 = alarm is operated by an original remote controller for central locking. RESET 3 = GSM
pager for cars with an installed car alarm. Performing the RESET instruction is indicated by 4 beeps.
Consequently, all settings, enrolled remote controllers and wireless detectors will be erased.
Not applicable
MASTER UC uuuu
User code setting – the code allows you to operate the alarm remotely via SMS from unauthorized phones.
uuuu is a new user code, 4 to 8 letters (A–Z & 0–9, case insensitive). Factory default user code is USER
Not applicable
MASTER MC xxxx Master code setting –xxxx is a new master code (A–Z & 0–9, case insensitive). The code allows you to
change the maintenance settings for the car alarm. Factory default master code is MASTER
TELn xx...x
MASTER TELn xx...x Setting of phone numbers to report alarms to n = 1 to 4
DIALn xx...x
MASTER DIALn xx...x Setting the phone numbers to dial using Hands free. n = A, B, 1, 2
DIP abcdefghij
MASTER DIP abcdefghij DIP parameter entry – see the DIP table
SET abcdefghij
MASTER SET abcdefghij SET parameter entry – see the SET table
DIP parameters
Description
DIP
0 1
A 0 = silent arming/disarming without siren chirps
1 = 10 ms siren chirps when arming/disarming (non backed-up siren)
2, 3, 4 ... 9 = siren chirps when arming/disarming (a siren of another
type) lasting 20, 30, 40, 50, 100, 200, 300 or 500 ms
B Silent alarm
Audible alarm
C
SMS alarm report only
SMS alarm report and siren sound
phone call
D SMS remote control not
confirmed by SMS reply
SMS remote control instructions
confirmed by SMS reply
E
0 = arming control by dialling-in disabled
1 = arming control by dialling from TEL1 enabled
2 = arming control by dialling from TEL1 and TEL2 enabled
3 = arming control by dialling from TEL1, TEL2 and TEL3 enabled
4 = arming control by dialling from all TEL1 to TEL4 enabled
F
Arming control by dialling
in is not confirmed by
SMS
Arming control by dialling in (see E)
is
confirmed by SMS to the phone
which called the car alarm
G
User can not change SMS
Texts
User can change SMS texts by TXT
Sequence
H
REARM disabled
If the car is not entered within 1
minute after disarming, it will REARM
I
0 = Immobilization by arming and by SMS instruction
1 = Immobilization by arming and automatically 5 minutes after
ignition is turned off (AUTOIMO) and also by SMS instruction
2 = Immobilization only by SMS instruction
3 = Immobilization and also by SMS instruction. If disarmed and
ignition is turned off for more than 60 minutes the SMS STATUS is
sent as an alert to possible forgotten arming.
J
Self-location disabled
The car’s location will be sent by SMS
after an IMO instruction has been
performed.
or if the car stops after an
immobilization
SMS instruction
Bold marked values = factory default
Steps to enroll RC-8x controllers:
1. The car alarm should be disarmed, with the ignition on.
2. Send the SMS instruction MASTER LEARN RC
3. The car alarm beeps 3 times and an LED starts to flash.
4. The RC-8x controller is enrolled by pressing buttons
and
simultaneously for approx. 3 sec. A siren chirp confirms the enrollment. By
enrolling the first remote control all other remote controls previously enrolled
will be erased (so enroll all the controllers intended for use, one by one).
5. Exit enrollment by turning the ignition off. The alarm confirms the enrollment by
sending an SMS message to authorized phones TEL1 to TEL4.
SET parameters
Description
SET
0 1
A 0 = open door signalling and INP activation while arming are both disabled
1 = open door signalling and INP activation while arming are both
enabled
2 = INP activation while arming enabled, open door signalling enabled with
a 10 second delay
3 = INP activation while arming enabled, open door signalling disabled
B
Voltage detector disabled
Voltage-drop detector enabled
C
lock / unlock signal duration (Reset 1)
0 = 0.5 / 0.5 sec (suitable for electromagnetic locks)
1 = 4 / 4 sec (suitable for pneumatic locks)
2 = 60 / 0.5 sec (suitable for automatic window closing)
D
DOOR input logic:
1 = activated by falling edge (grounding)
2 = activated by rising edge (disconnecting from GND)
E INP1 logic:
1 = activated by falling edge (grounding)
2 = activated by rising edge (disconnecting from GND)
F INP2 logic:
0 = activated by falling edge (grounding), it triggers an alarm also if
disarmed (24 hour reaction)
1 = activated by falling edge (grounding)
2 = activated by rising edge (disconnecting from GND)
G Central locking input logic: (Reset 2)
1 = activated by falling edge (grounding)
2 = activated by rising edge (disconnecting from GND)
H
0 = confirmation by turn lights for disarming is needed (Reset 2)
1 = confirmation by turn lights for arming and disarming is
needed
2= confirmation by turn lights for arming and disarming is not
needed so INP1 can be used as an alarm input
I
When armed, no monitoring of
GPS location changes
GPS location changes are
monitored when armed
J 0 = AUX output is a bus for communication with CR-11A modules
1 = AUX output provides power for external sensors
Bold marked values = factory default
Steps to enroll l detectors:
1. The car alarm should be disarmed, ignition on.
2. To enroll the internal detectors, send the SMS command MASTER LEARN
INT (To enroll the external detectors, send the SMS command MASTER
LEARN EXT )
3. The car alarm beeps 3 times and an LED starts to flash.
4. You can enroll a new detector to the system by inserting its batteries.If
you enroll a first detector, you will erase all detectors from the
associated groups (enroll all of them, which will be used in the group in
sequence).
5. Exit enrollment by turning the ignition off. The alarm confirms enrollment by
sending an SMS message to authorized phones TEL1 to TEL4.
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Jablotron CA-1803BT Athos at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Jablotron CA-1803BT Athos in the language / languages: English as an attachment in your email.

The manual is 0,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Jablotron CA-1803BT Athos

Jablotron CA-1803BT Athos User Manual - English - 16 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info