735607
1
Zoom out
Zoom in
Previous page
1/2
Next page
S
E
N
S
O
R
Gris/Grey/Grau
LF
HF
Ground wire
Cable cut detection
DIR
Blanc/White/Weiis
Marron/Brown/Braun
Vert/Green/Grün
Jaune/Yellow/Gelb
LF
S
E
N
S
O
R
Marron/Brown/Braun
Blanc/White/Weiss
2 fils/wire/leiter/hilos 5 fils/wire/leiter/hilos
* Pour les calibres 15 et 20 mm, version totalisateur 4/4 diviser les
valeurs du tableau par 10.
For sizes 15 and 20mm, 4/4 register divide by 10 the table values.
Für DN15 und DN20 beim 4/4 Zählwerk um Faktor 10 teilen.
Para los calibres 15 y 20 mm, versión totalizador 4/4 dividir los
valores de la tabla por 10.
** Diviser par 10 les valeurs du tableau concernant les Flostar M 40
mm fabriqués avant 1999 (numéro de série xxWEExxxxxx).
For 40mm Flostar M manufactured before 1999 (serial number
xxWEExxxxxx), divide the table values by 10.
Für Flostar M DN40 der Baujahre vor 1999 (Seriennummer
xxWEExxxxxx) um Faktor 10 teilen.
Dividir por 10 los valores de la tabla relacionados con los Flostar M
40mm fabricados antes de 1999 (número de serie xxWEExxxxxx).
Cyble
TM
Sensor
F Notice d’installation 2 & 5 fils
Installation instructions 2 & 5 wires
D Montageanleitung 2 & 5 Leiter
E Instrucciones de instalación 2 & 5 hilos
Les caractéristiques, cotes et schémas n’engagent Itron qu’après
confirmation / Itron is bound by the foregoing specifications only after confirmation.
9, rue Ampère
71031 Mâcon
France
Phone: +33 3 85 29 39 00
Fax: +33 3 85 29 38 58
www.itron.com
SYS-0005.4-ML-01.13 - SYMBOLE : A4001438-AF
© Copyright 2013, Itron, All Rights Reserved.
GAMME DE COMPTEURS/
METER RANGE/TYP/
GAMMA CONTATORI/
GAMA CONTADORES
Signal HF Signal BF / LF Signal / LF Ausgang / Señal BF
K = 1 K = 1 K = 2,5 K = 10 K = 25 K = 100 K = 1000
Aquadis+ 15* 1 L 1 L 2,5 L 10 L 25 L 100 L 1 m
3
Aquadis/TD8 15/20* 1 L 1 L 2,5 L 10 L 25 L 100 L 1 m
3
Aquadis 25/40* 1 L 1 L 2,5 L 10 L 25 L 100 L 1 m
3
65 10 L 10 L 25 L 100 L 250 L 1 m
3
10 m
3
Flodis 15/32 1 L 1 L 2,5 L 10 L 25 L 100 L 1 m
3
Narval/Unimag 15/20 1 L 1 L 2,5 L 10 L 25 L 100 L 1 m
3
Flostar M 40/150** 10 L 10 L 25 L 100 L 250 L 1 m
3
10 m
3
150 100 L 10 L 250 L 1000 L 2500 L 10 m
3
100 m
3
Woltamg M 50/100 10 L 10 L 25 L 100 L 250 L 1 m
3
10 m
3
50/125 10 L 10 L 25 L 100 L 250 L 1 m
3
10 m
3
Woltex M 50/125 10 L 10 L 25 L 100 L 250 L 1 m
3
10 m
3
150/300 100 L 100 L 250 L 1 m
3
2,5 m
3
10 m
3
100 m
3
400/500 1 m
3
1 m
3
2,5 m
3
10 m
3
25 m
3
100 m
3
1000 m
3
Poids d’impulsion / Pulse value / Impulswertigkeit /
Peso impulso
TARGET
Module fixation hook
CYBLE™ DETECTION
TEMPER / CABLE CUT
PULSE RF
TIC
TICCOF
PR05
DFC-MF
TM 255
Data
Logger
Blanc/White/Weiss
Blanc/White/Weiss LF +
Blanc/White/
Weiss LF +
Blanc/White/
Weiss LF +
Blanc/White/
Weiss LF +
Jaune/Tellow/
Gelb DIR
Blanc/White/Weiss LF +
Blanc/White/Weiss LF +
Vert/Green/Grün (Tamper)
Gris/Grey/Grau HF + (*)
Gris/Grey/
Grau HF +
Gris/Grey/
Grau HF +
Marron (Masse0V)/Brown (0V Ground)/
Braun (Masse GND)
Marron (Masse0V)/Brown (0V Ground)/
Braun (Masse GND)
Marron (Masse0V)/Brown (0V Ground)/
Braun (Masse GND)
Marron (Masse0V)/Brown (0V Ground)/
Braun (Masse GND)
Marron (Masse0V)/Brown (0V Ground)/
Braun (Masse GND)
Marron (Masse0V)/Brown (0V Ground)/
Braun (Masse GND)
Noir/Black/Schwarz
Noir/
Black/
Schwarz
Vert/Green/Grün
GND
Marron/Brown/
Braun (4)
Noir/Black/Schwarz
20 Hz
0 V
7
7
6
6
7
7
3
2
8
12
12
Input
Blanc/White/Weiss
Marron (Masse0V)/Brown (0V Ground)/
Blanc/White/
Weiss
Jaune/Tellow/
Blanc/White/
Weiss
Blanc/White/
CybleSensorV2_ig_ML.indd 1 10/11/2015 11:19
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Itron Cyble Sensor V2 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Itron Cyble Sensor V2 in the language / languages: English, German, French, Spanish as an attachment in your email.

The manual is 0,37 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info