686039
20
Zoom out
Zoom in
Previous page
1/21
Next page
254
A
S AVE THESE INSTRUCTIONS
(254IO) SPA ENGLISH 7.5” X 10.3” PANTONE 295U 01/28/2016
English
TROUBLESHOOTING
Page 20
NO DISPLAY/SPA
CONTROL UNIT DOES
NOT WORK
HOUSEHOLD CIRCUIT
BREAKER TRIPPED
NOT HEATING
PROPERLY
BUBBLE AIR BLOWER
DOES NOT WORK
FILTRATION PUMP
NOT WORKING
WATER NOT CLEAN
PUMP CONNECTORS
ARE NOT LEVEL WITH
THE SPA CONNECTORS
TUB HAS A STRANGE
SHAPE
TUB LOSES AIR
PRESSURE
LEAKING BETWEEN SPA
TUB CONNECTORS AND
CONTROL UNIT
CONNECTORS
SPA IS TOO NOISY IN
FILTRATION MODE ONLY
Spa is unplugged or off.
Control panel cable plug loose.
• Power failure.
• RCD tripped.
• RCD broken.
Circuit breaker under rated.
Overloaded circuit breaker.
An electrical fault in the line.
Temperature set too low.
• Dirty lter cartridge.
Water temperature decreasing during
heater STANDBY mode.
Heating element failed.
Air blower pump is too hot.
• Dirty lter cartridge.
Filtration inlet and/or outlet clogged.
Filter pump motor failed.
Cartridge assembly not properly attached.
• Insuf cient ltering time.
• Dirty lter cartridge.
Improper water maintenance.
Filtration inlet and outlet clogged.
One characteristic of PVC is that
it changes shape, which is normal.
Expanded internal air pressure by
strong sunshine.
Air valve cap loose.
Air valve base loose.
Hole, cut or split on spa tub.
Spa control base inlet/outlet connections
not securely tight.
Spa control base inlet/outlet o-ring
missing/dirty.
Control base components not securely
attached.
Control base ground not level and rm.
• Spa lter motor failed.
Ensure the spa is plugged and switched on.
Ensure the control panel cable plug is rmly
attached to the control base receptacle.
Check power source.
Reset the RCD.
Contact Intex Service Center.
Ensure correct circuit breaker rating.
Provide a dedicated circuit breaker feeding the
spa electrical outlet only.
Contact a qualify electrician to correct the
electrical fault.
Increase the temperature and attach the spa
cover.
Clean or replace the lter cartridge in time.
If heater is in STANDBY mode, press the ame button
twice to heat up the water to the set temperature.
Contact Intex Service Center.
Turn off and unplug the spa. Let it cool down and
restart all over again.
If problem persists contact Intex Service Center.
Clean or replace the lter cartridge in time.
Check and clean ltration inlet and outlet regularly.
Contact Intex Service Center.
Ensure the cartridge assembly is properly attached.
Increase ltration time.
Clean or replace the lter cartridge in time.
Keep the spa water properly sanitized. Refer to the
chemical manufacturer’s instructions.
Check and clean ltration inlet and outlet regularly.
Elevate the pump with wood or another type of
insulated material to bring the pump’s connectors
level with the spa’s connectors.
Do not expose the product under direct sunshine.
Check the air pressure and release air if necessary.
During very hot weather, you must check to see
whether it is necessary to release some air. This is
to avoid any possible damage to the tub.
Ensure air valve cap is securely closed.
Fill up the spa tub with air then make sure the
air valve base is tighten, see “Spa Tub Air Valve
Fastening” section.
Put liquid soap and water in a squirt bottle and spray on
seams. If there is a leak it will bubble. After you nd the leak,
clean and dry the leaking area, then apply the repair patch
that comes with your spa.
Tighten inlet and outlet connections.
Coat the o-ring with petroleum jelly for water proof.
Remove grid from inside spa with a screwdriver,
ensure inlet/outlet O-ring is in place, clean and not
damaged.
Ensure control panel, back cover and all inlet/outlet
are securely connected.
Ensure ground is level, rm and smooth.
Replace the failed lter motor with a new one.
PROBLEM CAUSE SOLUTION
20


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Intex PureSpa - 28474 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Intex PureSpa - 28474 in the language / languages: English as an attachment in your email.

The manual is 1,63 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Intex PureSpa - 28474

Intex PureSpa - 28474 User Manual - German - 24 pages

Intex PureSpa - 28474 User Manual - Dutch - 22 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info