TROUBLESHOOTING GUIDE
FILTER MOTOR
FAILS TO START
FILTER DOESN’T
CLEAN POOL
FILTER DOESN’T
PUMP WATER OR
THE WATER FLOW
IS VERY SLOW
PUMP DOESN’T
WORK
TOP COVER
LEAKING
HOSE LEAKING
AIR LOCK
INLET THREADED
AIR CONNECTOR/AIR
JET VALVE LEAKING
The motor is not plugged in.
The GFCI/RCD circuit breaker is
tripped.
Motor too hot and overload
protection is shut off.
Improper chlorine or pH levels.
Filter cartridge is dirty.
• Damaged cartridge.
Excessively dirty pool.
The strainer screen is restricting
the water flow.
Clogged inlet or discharge.
An air leak on the intake line.
Scale or buildup on cartridge.
Excessively dirty pool.
Dirty filter cartridge.
The nozzle and strainer connection
are reversed.
Inlet threaded air connector
connected to the wrong hole on
the liner.
• Low water level.
• Strainer screen plugged up.
• An air leak on the intake hose.
• Faulty motor or the impeller is jammed.
• An air lock inside the cartridge chamber.
• O-ring missing.
Cover or air release valve are not
tight.
Hose nuts are not well-fitted.
Hose o-ring dislodged when
connecting the hose.
• Hose broken.
There’s air trapped in the
pump housing and inlet hose.
The inlet and outlet hoses
connection are reversed.
Plunger valve not well-fitted.
Air jet valve is not tight and facing
up.
Air jet valve internal seal blocked.
Air jet valve internal seal dirty.
Air jet valve broken.
TROUBLE CAUSE SOLUTION
Filter cord must be plugged into a 3 wire outlet
that is protected by a Class A Ground Fault
Circuit Interrupter, or RCD.
Reset circuit breaker. If circuit breaker trips
repeatedly, your electrical system may have a
defect. Turn off circuit breaker and call an
electrician to correct the problem.
Let the motor cool down.
Adjust the chlorine and pH level. Consult
your local swimming pool supply stores.
Clean or replace cartridge.
Check the cartridge for holes. Replace if
damaged.
Operate the filter for longer periods.
Clean the strainer screen at the inlet.
Clear any obstructions in the intake hose by
discharging it inside pool wall.
Tighten hose nuts, check hoses for damage,
check pool water level.
Replace cartridge.
Clean cartridge more often.
Clean inside the plunger valve.
Pull valve handle to full upright position.
Install the nozzle at the upper position of pool
inlet, and the strainer at the lower position of
pool outlet.
Make sure the inlet threaded air connector is
connected to the pool inlet upper hole.
Fill pool to correct water level.
Clean strainer screens at pool inlet.
Tighten hose nuts, check hose for damage.
Clear any sticks or leaves in the intake hose.
Turn and pull valve handle to full upright
position.
Remove cover & check for O-ring.
Tighten cover or valve (Manually).
Tighten or reinstall hose nut.
Put the o-ring back into the groove.
Replace a new hose.
Open air release valves, wait until water
starts to flow out of the valves, then close it.
The lower position of pool outlet connects to
filter pump water inlet. The upper position of
pool inlet connects to filter pump water outlet.
Tighten or reinstall plunger valve.
Tighten air jet valve and make sure it’s facing
up.
Turn pump ON and run for few seconds,
then turn OFF, repeat 3 times.
Remove air jet valve, flush dirt out with water
and replace valve back.
Replace a new air jet valve.
14


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Intex Krystal Clear 634RC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Intex Krystal Clear 634RC in the language / languages: English as an attachment in your email.

The manual is 2,59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Intex Krystal Clear 634RC

Intex Krystal Clear 634RC User Manual - German - 16 pages

Intex Krystal Clear 634RC User Manual - Dutch - 17 pages


The manual is sent by email. Check your email