688780
16
Zoom out
Zoom in
Previous page
1/20
Next page
16
S
I
U
2.15
2.14
MAINTENANCE
Objects or structural obstacles (furniture, curtains,
plants, leaves, blinds, etc.) must not obstruct the normal
air flow both from the internal and from the external grids.
Do not lean against, or worse sit on, the body of the
conditioner, this would damage the appliance.
Do not move the horizontal air outlet flap manually. Always
use the remote control to perform such operation.
In the event of water leaks, turn off the appliance and
disconnect the electric power supply. Call the nearest
service centre.
During heating mode, the conditioner eliminates
periodically any ice formed on the external battery. In
such situation, the machine keeps on working, but it
does not dispense warm air to the room. This phase
can last from 3 up to maximum 10 minutes.
The appliance must not be installed in rooms where
explosive gases develop or where there are humidity
and temperature conditions that exceed the maximum
levels reported on the installation manual.
Clean the air filter regularly as described in the specific
paragraph.
Before leaving the site, the packaging should be gathered
up and all traces of dirt that have deposited on the unit
during assembly should be eliminated with a damp cloth.
These operations, which are not strictly necessary, in any
case allow for a more professional appearance of the
installation in the eyes of the user.
To avoid unnecessary calls by the user, before leaving the
site it is also a good idea to:
- outline the contents of the manual,
- show them how to clean the filter,
- explain when and how they should contact Customer
Service.
Use of the appliance
Operations after installation
Should any anomaly occur in the condensation water
system, the maximum level float blocks the conditioner
and the OF code appears on the display.
During cooling and dehumidification, electronics keeps the
water distribution system active with the battery - together
with the fan - to disperse excess water in the container.
If the problem persists, please contact the assistance
service.
During heating, condensation should drain freely through
the specific pipe. In the event of an alarm, check that
the condensation pipe is not bent or obstructed, thus
preventing the water from flowing out.
Evacuation of condensate water in the event of an emergency
If the presence contact is not closed, the appliance will
not start and the CPalarm appears on the display.
Open CP contact
Display indications Cause
E1 Faulty room temperature RT probe
E2 Faulty evaporative battery IPT probe
E3 Faulty outdoor air temperature OT probe
E4 Faulty conditioner battery OPT probe
E5 Faulty indoor air fan motor
E6 Faulty outdoor air fan
E7 Lack of communication with the display
E8 Compressor discharge probe failure (only for DC Inverter models)
If the conditioner blocks because of an alarm (see following
table), please communicate to the assistance centre the
code on the display to facilitate interventions.
Detecting possible faults
Press and hold the air exchange key ( ) for 10 seconds to
enable the function ("En" displayed); the dehumidification
and Auto functions are disabled (leaving active only
ventilation, heating and cooling) and the settable set range
is reduced from 22 to 28 in cooling mode and from 16 to
24 in heating mode).
Hotel function
16


Need help? Post your question in this forum.

Forumrules
1

Forum

innova-2.0

Reset search

  • i need a simple instruction on hoe to operate the remote control for the innova2.0vertical 10-12DC Inverter A/C unit this is for a nursing home where the residents need the simple example please help i checked the operators manual and its to much for them to comprehend thanks Submitted on 15-7-2022 at 15:49

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Innova 2.0 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Innova 2.0 in the language / languages: English as an attachment in your email.

The manual is 4,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Innova 2.0

Innova 2.0 User Manual - English - 28 pages

Innova 2.0 User Manual - Dutch - 20 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info