INTRODUCTION
The Infresco has been designed specifically to work with Infra Red Heaters, with a rating of 4kW it
will allow you to control a variety of heating and lighting solution.
The Infresco has a 1 to 10 step setting allowing you to find the optimum comfort setting in you
specific area. With energy saving a major factor in the design brief, once the Infresco is switched
on it will automatically manage the heating system. With a built in temperature sensor only
allowing the unit to switch on when required and a PIR that will detects a requirement for the
heater to switch on only when needed. An optional remote control allows for the unit to be fitted
out of the way so safety is paramount. The Infresco has a built in soft start function which will add
up to an additional 30% life to your heater lamp.
APPLICATIONS
Any application were high inrush current is an issue or control is required. Typical use is for Infra Red
Heating lamps, Garden lighting
FEATURES
Soft Start – up to 30% extended life of Lamp
Variable Control – Ability to find comfort level
Simple Installation – Ability to plug directly in 13A Plug with up to 3kW load
Energy Saving – Automated system. (Only heat when required)
Temperature Monitoring – If ambient temperature is above preset the Infresco unit remains
switched off
SAFETY FIRST
Please read these instructions before installing and operating this product. (See warning for
additional information).
Installation
The ideal site for the PIR to be mounted is approximately 2.5 + Meters of the floor. Ceiling
mounting is preferred but not essential
The PIR must not be mounted.
Directly in line of the lamps output
Highly reflective surfaces
Radiators or other thermostatically controlled heaters
Open door ways with people walking past
Commissioning
NOTE: On switch on the PIR takes 60 seconds to set before detection takes place
NOTE: The PIR continues to monitor the area and will reset to the set time every time it detects
movement.
Before testing ensure the wiring is correct. The temperature trip point has already been preset at
the factory. The timer is preset to 5 minutes.
The expected detection area can now be “walked tested” using the diagram shown in mind. The
area should be crossed in various directions to ensure coverage is as expected.
Display Features
Display shows ‘t’ The Infresco is turned OFF as the ambient temperature
is above the trip level set by TEMP. SET.
Display shows ‘F’ The Infresco is set to FULL output.
Display decimal point pulses The PIR input is waiting to be enabled i.e. no movement.
Display decimal point fully on The Infresco is in Standby mode pressing the remote
control POWER button will toggle the power ON and OFF.
You can check the remote control is transmitting by observing the decimal point flashing rapidly.
UijthovenInfrarood
Nijverheidstraat31
4261TKWijkenAalburgTheNetherlands
Phone:0031416532724
Fax:0031416532719
Email:info@uithoven.nl
Web:www.terrastopper.nl
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Infresco Dimmer 6Kw at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Infresco Dimmer 6Kw in the language / languages: English as an attachment in your email.

The manual is 1 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info