Getting started
1. Unpack the camera and remove the lens cap.
2. Press the Power switch and allow the camera to calibrate
itself. During this 15-second time period, the screen
may blank out before the thermal image appears.
3. Check the battery icon on the screen and charge unit
if necessary. The charging port is located inside the
camera flap. A full charge takes about 3.5 hours and
provides 6 hours of continuous use with the LED
flashlight on.
4. At this point, the camera should be ready for use with
the following defaults: Units of Measure: °F and Ft.;
Images are focused and aligned at 6’ from camera
lens; Image is blended at 50%; Auto tracking with
dual cursors is On; Voice/Text annotation is On;
Quick Start Guide
HeatSeeker™ Thermal Imager
Door
Screen
Power
Button
Navigation
Keys
F1 F2 F3 F4
then press the F2 key, until Visible Off appears. Then,
use the center nav key to toggle the feature On. Then,
use the right/left keys to adjust the image blend.
9. To freeze the image, press the F3 key. If unsatisfied
with the image, press F3 again to release the image
and enter the active measuring mode again. Press F3
to freeze another image.
10. For on-the-job troubleshooting, such as manually
moving the cursor to a specific location on the
camera’s screen to obtain a specific temperature
reading, refer to the full user’s manual saved on the CD.
11. To save the image to the Micro-SD card, press the
Capture button on the top of the camera. Then, record
a voice tag and/or text caption to identify the file when
retrieving it in the software. If these steps are skipped,
the image is still saved but with a generic file name.
12. The camera then returns to live imaging and is ready
to capture a new image.
13. The camera can be turned off by depressing the
power button until the camera shuts down. The
camera stores and uses the last settings upon the
next startup.
The F4 key can be used to enter the menu to change
settings and view saved images onscreen. Refer to the
operating manual to learn the camera’s full capabilities.
Ambient temperature is
set at 72°F; Emissivity is
set for 0.95; Auto Power
Off is set for 20min.
5. To customize the camera
from any of the defaults,
please see the Customizing
the Camera Setup section
further in this guide.
6. Point the camera at the
object of interest, noting that the camera is
focused/aligned at 6’. Ensure your fingers do not
obscure the small visual lens.
7. The dual cursors automatically locate the hottest and
coldest temperatures and displays these temperatures
at the top of the screen along with the Δ temperature.
8. To change the % image blend, hit the right/left
navigation keys. Note that the % refers to the amount
of visual image shown. If these keys are not working,
Capture Button
Thermal Lens
Visual Lens
Laser Button
Quick Start Guide: HeatSeeker™ Thermal Imager www.idealindustries.com
Soft Function Keys
a) 100% Thermal
Only
b) 100% Visible
Only
c) 50% Thermal
& 50% visible
12-3484 HeatSeeker 3-fold R 1/26/09 9:52 AM Page 5
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ideal HeatSeeker at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ideal HeatSeeker in the language / languages: English as an attachment in your email.

The manual is 1,2 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Ideal HeatSeeker

Ideal HeatSeeker User Manual - English - 22 pages

Ideal HeatSeeker Quick start guide - Dutch - 8 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info