ABOUT CE
INSTALLATION NOTES
For amateur base station installations it is recommended
that the forward clearance in front of the antenna array is
calculated relative to the EIRP (Effective Isotropic Radiated
Power). The clearance height below the antenna array can
be determined in most cases from the RF power at the
antenna input terminals.
As different exposure limits have been recommended for
different frequencies, a relative table shows a guideline for
installation considerations.
Below30MHz,therecommendedlimitsarespeciedin
termsofV/morA/meldsastheyarelikelytofallwithinthe
near-eldregion.Similarly,theantennasmaybephysically
short in terms of electrical length and that the installation will
require some antenna matching device which can create
local,highintensitymagneticelds.AnalysisofsuchMF
installations is best considered in association with published
guidance notes such as the FCC OET Bulletin 65 Edition
97-01 and its annexes relative to amateur transmitter
installations. The EC recommended limits are almost
identicaltotheFCCspecied‘uncontrolled’limitsandtables
exist that show pre-calculated safe distances for different
antenna types for different frequency bands. Further
information can be found at http://www.arrl.org/.
Typical amateur radio installation
Exposure distance assumes that the predominant radiation
pattern is forward and that radiation vertically downwards
is at unity gain (sidelobe suppression is equal to main lobe
gain). This is true of almost every gain antenna today.
Exposed persons are assumed to be beneath the antenna
array and have a typical height of 1.8 m.
Theguresassumetheworstcaseemissionofaconstant
carrier.
For the bands 10 MHz and higher the following power
density limits have been recommended:
10–50 MHz 2 W/sq m
Vertical clearance by EIRP output
1 Watts 2.1 m
10 Watts 2.8 m
25 Watts 3.4 m
100 Watts 5 m
1000 Watts 12 m
Forward clearance by EIRP output
100 Watts 2 m
1000 Watts 6.5 m
10,000 Watts 20 m
100,000 Watts 65 m
In all cases any possible risk depends on the transmitter
being activated for long periods. (actual recommendation
limitsarespeciedasanaverageduring6minutes)
Normally the transmitter is not active for long periods of
time. Some radio licenses will require that a timer circuit
automatically cuts the transmitter after 1–2 minutes etc.
Similarly some types of emission, i.e., SSB, CW, AM etc.
havealower‘average’outputpowerandtheassessedrisk
is even lower.
List of Country codes (ISO 3166-1)
Country Codes Country Codes
1 Austria AT 18 Liechtenstein LI
2 Belgium BE 19 Lithuania LT
3 Bulgaria BG 20 Luxembourg LU
4 Croatia HR 21 Malta MT
5 Czech Republic CZ 22 Netherlands NL
6 Cyprus CY 23 Norway NO
7 Denmark DK 24 Poland PL
8 Estonia EE 25 Portugal PT
9 Finland FI 26 Romania RO
10 France FR 27 Slovakia SK
11 Germany DE 28 Slovenia SI
12 Greece GR 29 Spain ES
13 Hungary HU 30 Sweden SE
14 Iceland IS 31 Switzerland CH
15 Ireland IE 32 Turkey TR
16 Italy IT 33 United Kingdom GB
17 Latvia LV
172


Need help? Post your question in this forum.

Forumrules
1

Forum

icom-ic-7300

Reset search

  • is there available a wiring pictorial chart for the small internal ic-7300 coaxial jumper cables?
    ie: from the RF unit to the PA board? tnx Sam in Alabam KF4TXQ Submitted on 2-1-2022 at 06:09

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Icom IC-7300 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Icom IC-7300 in the language / languages: English as an attachment in your email.

The manual is 24,44 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info