Set scan type (Priority or Normal scan) and scan resume timer
in advance, using Set mode.
q While pushing [H/L], push [DIAL•DW ] several times to
select the desired channel group (depending on the con-
nected transceiver’s version).
w Set TAG channels as described at previous item.
e Make sure the squelch is closed to start a scan.
r Push [SCAN•TAG] to start Pri-
ority or Normal scan.
•“
PPRRII--SSCCAANN 1166
”or “
NNOORRMMAALL
SSCCAANN
” appears during Priority
or Normal scan, respectively.
When a signal is detected, scan
pauses until the signal disap-
pears or resumes after pausing
5 sec. according to the Set mode
setting (Channel 16 is still moni-
tored during Priority scan).
• Rotate [SELECTOR
DIAL
] to check the scanning TAG chan-
nels, to change the scanning direction or resume the scan
manually.
•“
1166
blinks at the channel comment indicator and a beep tone
sounds when a signal is received on Channel 16 during Prior-
ity scan.
t To stop the scan, repeat step r.
BUSYBUSY-25W25W------INTINT---CALL---CALL
LOCAL--DUPLOCAL--DUP
SCRAMSCRAM----TAGTAG
NORMALNORMAL-SCANSCAN
-34"34.206N34"34.206N
123"23.236W123"23.236W
----UTCUTC-10:10COMMERCIAL10:10COMMERCIAL
[DIAL][DIAL]
During normal scan
Appears
GRP
2 Monitor function
, Call channel programming
. Dualwatch/Tri-watch operation
0 Setting TAG channels
1 Starting a scan
The monitor function releases the noise squelch mute of the
microphone only. (An independent noise squelch system is
employed.)
Push
[VOL/SQL•MONI ]
for
1 sec. to activate the Monitor
function.
•“
BBUUSSYY
” blinks and audio is emit-
ted.
[VOL/SQL•MONI ] (or [ENT],
[CLR])
cancels the Monitor func-
tion
.
L
L
BUSYBUSY-25W25W------INTINT---CALL---CALL
LOCAL--DUPLOCAL--DUP
SCRAMSCRAM--TAG--TAG
NORMAL-SCANNORMAL-SCAN
-34"34.206N34"34.206N
123"23.236W123"23.236W
----UTCUTC-10:10COMMERCIAL10:10COMMERCIAL
[VOL][VOL]
Blinks
q While pushing [H/L], push
[DIAL•DW ] several times to
select the desired channel group
(depending on the connected
transceiver’s version) to be pro-
grammed.
w Push [16•C] for 1 sec. to select
call channel of the selected chan-
nel group.
•“
CCAALLLL
” and call channel number
appear.
e Push [16•C] again for 3 sec. (until
a long beep changes to 2 short
beeps) to enter the call channel
programming condition.
The channel number to be pro-
grammed blinks.
r Rotate [SELECTOR
DIAL
] to select
the desired channel.
t Push [16•C] to program the dis-
played channel as the call channel.
The channel number stops blinking.
• Push [DIAL] to cancel.
BUSY
-25W---INT---CALL
LOCAL--DUP
SCRAM--TAG
NORMAL-SCAN
-34"34.206N
123"23.236W
--UTC-10:10- INTL
[DIAL]
BUSY
-25W---INT---CALL
LOCAL--DUP
SCRAM--TAG
NORMAL-SCAN
-34"34.206N
123"23.236W
--UTC-10:10- INTL
[DIAL]
BUSY
-25W---INT---CALL
LOCAL--DUP
SCRAM--TAG
NORMAL-SCAN
-34"34.206N
123"23.236W
--UTC-10:10-CALLING
[DIAL]
BUSY
-25W---INT---CALL
LOCAL--DUP
SCRAM--TAG
NORMAL-SCAN
-34"34.206N
123"23.236W
--UTC-10:10-CALLING
[DIAL]
GRP
BUSY
-25W---INT---CALL
LOCAL--DUP
SCRAM--TAG
NORMAL-SCAN
-34"34.206N
123"23.236W
--UTC-10:10- VTS
[VOL]
q Select Dualwatch or Tri-watch in Set mode.
w Rotate [SELECTOR
DIAL
] after pushing [DIAL•DW ] to
select the desired channel.
While pushing [H/L], push [DIAL•DW ] several times to
select the channel group (depending on the connected trans-
ceiver’s version)
, if desired.
e Push [DIAL•DW ] for 1 sec.
to start Dualwatch or Tri-watch.
•“
DDUUAALL 1166
” appears during Du-
alwatch; “
TTRRII 1166
” appears
during Tri-watch.
•Abeep tone sounds when a sig-
nal is received on Channel 16.
•Tri-watch becomes Dualwatch
when receiving a signal on the
call channel.
r To cancel Dualwatch or Tri-watch, push [DIAL•DW ]
again.
GRP
GRP
BUSYBUSY-25W25W------INTINT---CALL---CALL
LOCAL--DUPLOCAL--DUP
SCRAMSCRAM--TAG--TAG
--------DUALDUAL-1616
-34"34.206N34"34.206N
123"23.236W123"23.236W
----UTCUTC-10:10COMMERCIAL10:10COMMERCIAL
[VOL][VOL]
Appears
GRP
GRP
q While pushing [H/L], push [DIAL•DW ] several times to
select the desired channel group (depending on the con-
nected transceiver’s version).
w Push [DIAL•DW ] then rotate [SELECTOR
DIAL
] to se-
lect the desired channel to be set as a TAG channel.
e Push [SCAN•TAG] for 1 sec. to set the displayed channel
as a TAG channel.
•“
TTAAGG
” appears in the display.
r To cancel the TAG channel setting, repeat step e.
•“
TTAAGG
” disappears.
Clearing (or setting) all tagged channels
While pushing [H/L], push [SCAN•TAG] for 3 sec. (until a long
beep changes to 2 short beeps) to clear all TAG channels in
the channel group.
Repeat above procedure to set all TAG channels.
GRP
GRP
4
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Icom HM-162E at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Icom HM-162E in the language / languages: English as an attachment in your email.

The manual is 0,14 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info