RTH1120 69-1875EF 22/2/06 1/4
The RTH110B non-programmable thermostat can be used to con-
trol:
a gas, fuel oil or electric furnace - 2 or 3 wires
a central air conditioner - 2 or 3 wires
a hot water system with or without pump - 2 wires
a millivolt system - 2 wires
a central heating and cooling system - 4 or 5 wires
Note: This thermostat is not compatible with heat pumps or multi-
stage systems.
Features
System operating mode selection: heat, cool or off
Fan operating mode selection: automatic or on (continuous)
Programmable heating and cooling cycle lengths: 10, 12, 15, 20
or 30 minutes
Temperature display in °F or °C
Backlit display
Battery replacement indicator
Interchangeable faceplates (titanium, charcoal & taupe)
2.1 Removing the Old Thermostat
IN ORDER TO AVOID ANY RISK OF ELECTRIC SHOCK, CUT
POWER TO THE HEATING SYSTEM.
n Remove the old thermostat to access the wires.
Attention: If the old thermostat was mounted onto an electrical box,
it was probably powered by 120/240 volts. In this case, this thermo-
stat cannot be used.
o Identify and label each wire (with the corresponding letter on
the wire terminal) and remove them from the terminals.
p If necessary, strip the end of each wire (maximum of 1/4 inch).
q Wrap the wires around a pencil to prevent
them from falling into the wall.
r If the hole in the wall is too big, insulate it
using a non-flammable material in order
to avoid air draughts behind the thermo-
stat.
2.2 Installing the New Baseplate
For a new installation, choose a location approximately 5 feet
(1.5 m) above the floor and on an inside wall. Avoid draughty
areas (top of staircase, air outlet, etc.), dead air spots (behind
doors), direct sunlight or areas near concealed pipes or chim-
neys.
n Remove the thermostat faceplate.
o Loosen the locking screw to separate the thermostat from its
baseplate (the screw cannot be completely removed).
p Tilt the thermostat upwards.
q Mark and bore the appropriate mounting holes (using a 3/16”
drill bit) or use the existing holes. Insert the plastic anchors.
r Pass the wires through the opening of the baseplate and fix the
baseplate to the wall using the screws provided.
2.3 Connecting the Thermostat
Refer to the following table for matching the wire labels with the
thermostat terminals.
Note: Do not connect wires identified as C, X or B. Wrap the bare
end of these wires with electrical tape.
Important: The red jumper wire between Rh and Rc terminals must
be removed in a 5-wire installation.
1. Introduction
2. Installation
RTH1120
Non-programmable Electronic Thermostat
Installation and User Guide
Display
Adjustment
buttons
System operating
mode selector
Fan operating
mode selector
Backlight
button
RTH2520 terminals Description Wire labels
Rh Heating power supply Rh, R, 4, V
Rc Cooling power supply Rc, R
W Heating signal W, W1, H
Y Cooling signal Y, Y1, M
GFan G, F
1


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell RTH1120 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell RTH1120 in the language / languages: English as an attachment in your email.

The manual is 0,52 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info