3.2 Unsuitable locations
Do not place the CO alarm in any of the following areas.
In an enclosed space (for example in a cupboard or behind a curtain).
Where it can be obstructed (for example by furniture, curtains, etc.).
In a damp or humid area, e.g. Bathrooms, Wet rooms, etc.
Directly above a sink, cooker, steaming pots or kettles.
Next to an extractor fan, air vent, door, window or similar ventilation openings.
Over heat sources such as radiators or hot air vents.
Where the temperature could drop below –10°C or rise above 40°C and never outside.
Where dirt or dust could block the sensor.
Near paint, thinners, solvent fumes or air fresheners.
If locating the CO alarm in a room with a fuel burning appliance (see figure 1)
If the alarm is mounted on a wall, it should be located at a height greater than the height
of any door or window but still be at least 15 cm from the ceiling.
If it is mounted on the ceiling it should be at least 30 cm from any wall or light fitting.
The CO alarm should be a horizontal distance of between 1m and 3m from the potential
CO source.
If there is a partition in the room, the CO alarm should be located on the same side of the
partition as the potential source.
In rooms with sloped ceilings, the CO alarm should be located at the high side of the
room (see fig 2).
If locating the CO alarm in a bedroom or in rooms remote from a fuel burning
appliance (see figure 3)
Mount the CO alarm relatively close to the breathing zone of the occupants.
Whatever position is chosen make sure it is possible to view the three light indicators, when
in the vicinity of the alarm.
WARNING: Do not use the CO alarm on an intermittent basis, or as a portable
detector.
4 Installation Procedure
1. Select a suitable location (paragraph 3.1).
2. Remove the mounting plate from the packaging/alarm.
3. Place the mounting plate on the ceiling or wall exactly where you want to mount the
alarm. With a pencil, mark the location of the two screw holes.
4. Take care to avoid any electrical wiring already present in the ceiling or the wall; drill
holes using a 5.0mm drill bit through the centre of the marked locations. Push the
plastic screw anchors provided into the drilled holes. Screw the mounting plate to the
ceiling or wall.
5. Do not mount the cover on the base when switch is on position “X” (figure7).
6. Carefully line up the alarm on the base, then press home & twist on (this connects the
batteries). The red, amber & green lights will immediately flash in sequence to show
they are working.
7. Press the test button (after 15 seconds) to ensure that the alarm works.
8. Install all the other alarms similarly.
4.1 How to tamperproof the alarm
It is possible to protect against unauthorized removal of the alarm. Break off the small pillar
on the base of the alarm as shown in figure 4. To remove the alarm, use a small screwdriver
to release the catch (push the catch towards the ceiling) and then twist off the alarm
(figure 5).
If necessary it is possible to further secure or tamperproof the alarm by using a No.2 or No.4
self tapping screw (2 to 3mm diameter by 6 to 8mm long- not supplied), to firmly lock the
alarm and its mounting plate together (figure 6).
5 Registering the Detector
Registration is the procedure that associates the detector with the evohome security hub.
1.
2. Remove and re-fit the unit to the wall mount.
3. A confirmation message appears after several seconds (up to 10 sec), indicating
registration of the sensor at the evohome security hub.
4. Two beeps will confirm the successful enrolment. always register a sensor in its final
position.
Note: The switch on the PCB is for manufacturing purposes only (this is not for
registration).
https://
WEB*
*https://international.mytotalconnectcomfort.com
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Honeywell CO8MS at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Honeywell CO8MS in the language / languages: English, German, Dutch, French, Italian, Portuguese, Spanish as an attachment in your email.

The manual is 1,11 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Honeywell CO8MS

Honeywell CO8MS User Manual - English - 14 pages

Honeywell CO8MS User Manual - German - 14 pages

Honeywell CO8MS User Manual - Dutch - 14 pages

Honeywell CO8MS Quick start guide - All languages - 2 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info