Congratulations, The Harman® Allure50 pellet stove you
have selected is designed to provide the utmost in safety,
reliability,ande󰀩ciency.
Astheownerofanewpelletstove,you’llwanttoreadand
carefullyfollowalloftheinstructionscontainedinthisowner’s
manual. Pay special attention to all cautions and warnings.
Thisownersmanual shouldberetainedforfuturereference.
We suggest that you keep it with your other important
documents and product manuals.
Your new Harman® Allure50 Freestanding Pellet Stove will
giveyouyearsofdurableuseandtrouble-freeenjoyment.
Welcome to the Harman® family!
Note: Cast iron is an artisan crafted material, which is
made the same way today as nearly 2000 years ago.
Due to the intrinsic primitive nature of the casting
process, part to part variation is normal and adds to the
character of a hand built cast iron appliance
Read this manual before operating this appliance.
Please retain this Owners Manual for future reference.
Read the Installation Manual before making any installation or nishing changes.
Listing Label Information/Location Themodelinformationregardingyourspecicstovecanbefoundonthe
rating plate usually located in the control area of the stove.
BARCODE LABEL
HF
Serial No.
No de série:
MODEL / MODÈLE: “Allure50”
Room Heater Pellet Fuel-Burning Type
SUITABLE FOR MOBILE-HOME INSTALLATION
This pellet burning appliance has been tested and listed for use In
Manufactured Homes In accordance with OAR 814-23-900 through 814-23-909
352 Mountain House Road, Halifax, PA 17032 (É.-U.)
US ENVIRONMENTAL PROTECTION AGENCY
Certied to comply with 2015 particulate emission standards. Not approved for sale after May 15, 2020.
Certié conforme aux normes 2015 d’émission de particules. Non approuvé pour la vente après le 15 mai 2020.
Test to/testé à: ASTM E 2779-10, ASTM E 2515-
11, ASTM E 1509-12, ULC-S627-00, EPA Method
28R
Test date: September 2015
Room Heater, Pellet Fuel-Burning Type, Also For
Use In Mobile Homes. (UM) 84-HUD
“PREVENT HOUSE FIRES” Install and use only
in accordance with manufactures installation and
operation instructions.
Contact local building or re ofcials about
restrictions and installation inspection in your
area.
WARNING: FOR MANUFACTURED HOMES:
Do not install appliance in a sleeping room. An
outside combustion air inlet must be provided.
The structural integrity of the manufactured home
oor, ceiling and walls must be maintained.
Refer to manufacturer’s instructions and local
codes for precautions required for passing
chimney through a combustible wall or ceiling.
Inspect and clean exhaust venting system
frequently in accordance with manufacturer’s
instructions.
Use a 3” or 4” diameter type “L” or “PL” venting
system.
Do not connect this unit to a chimney ue
servicing another appliance.
Do not obstruct the space beneath the heater.
FOR USE WITH PELLETIZED WOOD FUEL
ONLY.
EPA Certied Emissions: 1.49 g/hr
Input Rating Max: 6.6 lb. fuel/hr
Electrical Rating: 240 VAC, 50 Hz, Start 1.75
AMPS, Run 1.25 AMPS
U.S. Electrical Rating: 115 VAC, 60 Hz, Start 3.5
AMPS, Run 2.5 AMPS
Fuel Type: Wood Pellet ONLY
Route power cord away from unit.
OPERATE ONLY WITH DOORS CLOSED
6"
2"
6.25"
6.25"
AC
B
MINIMUM CLEARANCES TO
COMBUSTIBLES
Back Wall to Appliance 2”
Side Wall to Appliance 6"
Corner Installation
Walls to Appliance 6.25”
Use a non-combustible oor protector
extending under and to the sides, front
and back of the unit as shown in oor
protection diagram. Measure front
distance from the surface of the glass
door.
Recommended: Non-combustible
oor protection extended beneath
the ue pipe when installed with
horizontal venting.
Floor Protection*
USA CANADA
Sides (A) 6” 152 mm
Back (B) 1” 25 mm
Front (C) 6” 152 mm
Alcove Installation
Min. Alcove Height 42” (1067mm)
Max. Alcove Depth 24” (610mm)
Report #/Rapport #0135PS037S
Modèle: ALLURE50
Appareil de chauffage à granulés de bois
CONÇU POUR MAISONS MOBILES
DANGER: Risque d’électrocution. Coupez l’alimentation
électrique avant l’entretien.
Remplacer le verre avec 5 mm miroir verre céramique de
la même qualité disponible auprès de votre revendeur.
En tenant la porte d’entrée et le couvercle de la trémie
hermétiquement fermé pendant le fonctionnement de
l’appareil
DISTANCES DE SECURITE PAR RAPPORT AUX
MATERIAUX COMBUSTIBLES
Paroi arrière à l’appareil 51 mm
paroi latérale de l’appareil 152 mm
Installation en angle
Entre murs et apparell 159 mm
Installation en alcôve
Hauter minimale de l’alcôve 1295 mm
Profondeur maximale de l’alcôve 610 mm
PROTECTION DU SOL*
Côtés (A) 152 mm
Arrière (B) 25 mm
Avant (C) 152 mm
Utiliser une protection de sol non combustible sous
l’appereil qui s’étend sur les côtes, l’avant et l’arrière du
poêle (voir schéma). Pour la distance à l’avant, mesurer
à partir de la surface de la porte en verre.
ll est recommendé que la protection s’étende jusque sous
le conduit en cas d’installation d’un conduit horizontal ou
sous le té en cas conduit vertical.
Do not remove this label/Ne pas enlever cette
étiquette.Made in the USA/Fabriqué aux É.-U.
3-90-088_R4
DANGER: Risk of electrical shock. Disconnect power supply before servicing.
Replace glass only with 5mm ceramic available from your dealer.
For further instruction refer to owner’s manual.
Keep viewing and ash removal doors tightly closed during operation.
Test pour / tested à la norme ASTM E 2779-10, ASTM E 2515-
11, ASTM E 1509-12, ULC-S627-00, EPA Method 28R
Chauffe-chambre, Pellet à combustibles Type, également pour
les maisons mobiles. (UM) 84-HUD
"Empêcher MAISON incendies" Installer et utiliser
uniquement en conformité avec les instructions du fabricant
d'installation et d'exploitation.
Contactez le service des incendies à propos des restrictions et
l'inspection d'installation dans votre région.
AVERTISSEMENT: POUR maisons préfabriquées: Ne pas
installer l'appareil dans une chambre à coucher. Une entrée
d'air de combustion à l'extérieur doit être fournie. L'intégrité
structurale de la maison étage, plafond et murs fabriqués doit
être maintenue.
Reportez-vous aux instructions du fabricant et les codes
locaux pour les précautions nécessaires pour faire passer
la cheminée à travers un mur ou un plafond combustible.
Inspectez et nettoyez système d'évacuation souvent en
conformité avec les instructions du fabricant.
Utilisez un "ou 4" Type de diamètre «L» 3 ou le système de
ventilation "PL".
Ne pas connecter cet appareil à un conduit de cheminée
desservant un autre appareil.
Ne pas obstruer l'espace sous le chauffe-eau.
À UTILISER AVEC LA GRANULE DE BOIS SEULEMENT.
Émissions certiés EPA: 1,49 g / h
Entrée Max Note: £ 6,6 carburant / h
Note électrique: 240 VAC, 50 Hz, Lancer 1,75 AMPS,
Exécuter 1,25 AMPS
US Note électrique: 115 VAC, 60 Hz, 3,5 AMPS Démarrer,
Exécuter 2,5 AMPS
Type de carburant: Bois Pellet SEULEMENT
Route cordon électrique de l'appareil.
Fonctionner uniquement avec les portes fermées
Date of Manufacture / Date de fabrication:
2017 2018 2019 JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
Manufactured by / Fabriqué par: Hearth and Home Technologies 352 Mountain House Road, Halifax PA 17032
LABEL TICKET
ECO: 85046 LABEL SIZE: 5.75” H x 13” W
PART # / REV: 3-90-088_R4 ADHESIVE:
ORIGINATOR: Spidlet MATERIAL: 24 Gauge Aluminum
DATE: 04/17/17 INK: Black Background
(4) Slotted Hole Size = .156 x .25
(4) Corners = R.062
This unit will need the addendum label that refers to the
“Wood heater needs periodic inspection” Information
352 Mountain House Road
Halifax, PA 17032
NO LITERATURE IN
THIS AREA
Model Name SerialNumber
EXAMPLE
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Harman Allure 50 - Pellet at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Harman Allure 50 - Pellet in the language / languages: English as an attachment in your email.

The manual is 5.27 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Harman Allure 50 - Pellet

Harman Allure 50 - Pellet User Manual - French - 26 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info