14.1. Fault error code Fxxx
Code
Cause:
Correction:
F001
A. STL triggered due to overheating
B. Fuse (F1) in the central unit is defective
C. Ignition short circuit
A. If STB has triggered - contact service
department
B. Fuse F1(3.15 A) defective - contact service
department
C. Ignition defective - contact service department
F002
A. Burner dirty
B. Pellet tank empty
C. Ignition defective
D. Burner not lying flush
E. Flame temperature sensor defective
F. Downpipe / screw conveyor blocked
G. Screw motor defective
A. Clean burner
B. Clean burner - fill pellet tank
C. Ignition defective - contact service department
D. Clean burner - position burner correctly
E. Flame temperature sensor defective - contact
service department
F. Clean the intake on the screw conveyor
housing with a vacuum cleaner - clean burner
G. Screw motor defective - contact service
department
F003
A. Heat exchanger / smoke flues dirty
B. Heating curve set too low
C. Room temperature sensor is lying on the
floor or wall
A. Cleaning the smoke flues - clean burner
B. Clean burner - Adjust heating curve as
described
C. Clean burner - suspend room temperature
sensor freely
F005
A. Burner dirty
B. Pellet tank empty
C. Downpipe / screw conveyor blocked
D. Room too airtight required combustion
air cannot flow into the room
E. Flue gas temperature sensor defective
F. Screw motor defective
G. Pellet fuel has too low a calorific value
A. Clean burner
B. Clean burner - fill pellet tank
C. Clean the intake on the screw conveyor
housing with a vacuum cleaner. Clean
burner
D. Clean burner - Ensure adequate combustion
air
E. Flue gas temperature sensor defective -
contact service department
F. Screw motor defective - contact service
department
G. Clean burner - switch to high quality pellet
type
F006
A. Combustion chamber door open during
operation
B. Damper in front of the door contact switch
not in the right position
C. Cable broken in the electric wiring to the door
contact switch
D. The connector has come out on the door
contact switch or on the central unit
A. Clean burner - close door
B. Clean burner - Adjust damper in front of the
door contact switch
C. Cable broken on door contact switch - contact
service department
D. Contact service department
F007
A. Flue gas temperature sensor defective or
not connected
A. Contact service department
F008
A. Flue gas temperature sensor defective
A. Contact service department
F009
A. Note: Combustion chamber door open
during “Off or standby”
A. No correction necessary - Close door - Error is
automatically cleared
F011
A. Room temperature sensor defective or
not connected
A. Contact service department
F012
A. Room temperature sensor defective
A. Contact service department
F015
A. Induced draught fan defective
B. Power supply to the fan motor interrupted
A. Contact service department
B. Check cable - contact service department
F018
A. Power cut
A. Clean burner - Clear error 018
17


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Haas-Sohn PALLAZZA-RLU 518.08 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Haas-Sohn PALLAZZA-RLU 518.08 in the language / languages: English as an attachment in your email.

The manual is 0.59 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Haas-Sohn PALLAZZA-RLU 518.08

Haas-Sohn PALLAZZA-RLU 518.08 Usermanual and installation guide - German - 34 pages

Haas-Sohn PALLAZZA-RLU 518.08 User Manual - French - 22 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info