704517
4
Zoom out
Zoom in
Previous page
1/9
Next page
1
GBGB
Application
Can be used in conjunction with:
Pressurised storage heaters
• Thermally-controlled instantaneous heaters
• Hydraulically-controlled instantaneous heaters
Operation with unpressurised storage heaters (displacement
water heaters) is not possible.
The water filtrate is classified as Category 2 according
to EN 1717.
Safety notes
Avoid danger due to damaged power cords. In the
case of damage, the control unit must be replaced by
the manufacturer or his customer service department
or an equally qualified person.
• The filter system must always be operated with cold water
of foodstuff grade.
The control unit and plug must not be directly or indirectly
sprayed with water when cleaning.
The control unit must be connected to a permanent power
supply.
At the installation location, the filter system must be
protected against mechanical damage, heat and direct
sunlight.
Do not install near heat sources or an open fire.
Installation of the fitting with filter cartridge is only permitted
in frost-free rooms.
Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification.
Technical data
Electrical data:
Voltage supply: 100 - 240 V AC / 50/60 Hz
Power consumption: 9 W
Standby power loss: < 1.0 W
• Type of protection
– Control unit: IP 68
– Mains plug: IP 40
Sanitary data:
• Flow pressure:
– min. 0.1 MPa
– recommended 0.2 – 0.5 MPa
• Operating pressure
– Fitting: max. 0.8 MPa
– Filter cartridge and filter head: 0.2 – 0.8 MPa
Test pressure of fitting: 1.6 MPa
If static pressures exceed 0.5 MPa, a pressure-reducing valve
must be installed.
Avoid major pressure differences between hot and cold water
supply.
Flow rate at 0.3 MPa flow pressure
– Fitting (tap water): approx. 9 l/min
– Filter cartridge (GROHE Blue
®
water): approx. 3.5 l/min
Ambient temperature: 4 – 32 °C
• Temperature
– Hot water inlet: max. 70 °C
– Recommended (energy saving): 60 °C
Adjustable bypass, factory setting: 2
Filter capacity at bypass setting 2
(Carbonate hardness 10 - 24 °KH): max. 750 liters
corresponds to max. 12 months
Water connection: cold - blue
hot - red
Electrical test data
• Software class: A
• Contamination class: 2
Rated surge voltage: 2,500 V
Temperature for ball impact test: 100 °C
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
Approval and conformity
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
Electrical installation
Electrical installation work must only be performed
by a qualified electrician. This work must be
carried out in accordance with the regulations
according to IEC 60364-7-701 (corresponding
to VDE 0100 Part 701) as well as all national and
local regulations.
Installation
Refer to the dimensional drawings on fold-out page I.
Install fitting, see fold-out page II, Figs. [1] and [2].
Important: The cable must not be pinched.
Flush pipes thoroughly before and after installation
(observe EN 806)!
Install control unit, see Figs. [3] and [4].
Important: Do not connect voltage supply yet.
Connect fitting, see Figs. [2], [5] to [7].
Open hot and cold water supply and check that
connections are watertight.
Connect voltage supply via mains plug, see Fig. [8].
The display illuminates and the remaining filter capacity is
displayed in percent.
This product conforms to the requirements of the
relevant EU guidelines.
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Grohe Blue Pure at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Grohe Blue Pure in the language / languages: English as an attachment in your email.

The manual is 0,93 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Grohe Blue Pure

Grohe Blue Pure User Manual - All languages - 92 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info