GB
Application
Can be used in conjunction with:
Pressurised storage heaters
Thermally controlled instantaneous heaters
Hydraulically controlled instantaneous heaters
Operation with unpressurised storage heaters (= open water
heaters) is not possible.
Technical data
Flow pressure
- min. 0.5 bar
- recommended 1 - 5 bar
Operating pressure max. 10 bar
Test pressure 16 bar
A pressure reducing valve must be fitted in the supply line if
static pressures exceed 5 bar to satisfy noise level ratings.
Avoid major pressure differences between hot and cold water
supply.
Flow rate at 3 bar flow pressure: approx. 27 l/min
Temperature
Hot water inlet: max. 80 °C
Recommended (energy saving): 60 °C
Scalding protection possible by fitting a temperature limiter
(see Replacement parts, fold-out page II, Prod. no.: 46 375).
Water connection hot - left
cold - right
Note (29 067):
This fitting can be combined with head and hand shower sets
by using a 3-way diverter.
Important note:
Never install shut-off valves in the outlet pipe (mixed
water) downstream of any built-in mixer.
Installation
Prepare the wall for the installation.
Prepare the holes for the single lever mixer and slots for the
pipes.
Align single lever mixer using fitting template and fit,
see fold-out page I, Figs. [1] and [2].
Permissible tolerances are given on the dimensional
drawing.
The arrow on the fitting template must point upwards.
To align place a spirit level on the cam on the fitting
template (A), see Fig. [1].
The finished surface of the wall (B) must lie within the
area (X) of the fitting template, see Fig. [2].
The cold water supply must be connected on the right, hot
water supply on the left.
Connect pipes.
Open cold and hot-water supply and check connections
for water-tightness.
Flush piping system prior and after installation of fitting
thoroughly (Consider EN 806)!
Plaster and tile the wall.
Do not remove the fitting template before final installation.
Final installation
Remove fitting template.
Note:
First fit the diverter (D) if installing trim set 29 061, see fold-out
page I, Fig. [3].
1. Remove screw plug (E).
2. Screw diverter (D) into position using 17mm socket spanner
and tighten.
Flow rate limiter
This mixer is fitted with a flow rate limiter, permitting an
infinitely variable individual reduction in flow rate. The highest
possible flow rate is set at the factory before despatch.
The use of flow rate limiters in combination with hydraulic
instantaneous heaters is not recommended.
To activate, see Fig. [4].
Install escutcheon and lever, see Figs. [5] and [6].
If the escutcheon can not be pushed far enough onto the cap,
an extension (see replacement parts, fold-out page II,
Prod. no.: 46 807 = 25mm / 46 808 = 50mm) must also be
installed.
Additionally seal the top edge of the escutcheon with silicone
when fitting against a particularly rough surface (deep tile
joints, highly textured tile).
Check mixer for correct operation, see fold-out page III,
Fig. [7].
Function of automatic diverter (D), see Fig. [8].
Pulling the lever will release water delivery.
On the bath mixer, water will always emerge from the lower
outlet first (e.g. bath outlet).
Pressing diverter (D) shuts off the flow of water to the bath and
delivers water to the shower outlet.
When the mixer is closed, the diverter is released
automatically so that when the mixer is opened again, water
will always emerge from the lower outlet first (e.g. bath outlet).
Maintenance
Inspect and clean all parts, replace as necessary and lubricate
with special grease.
Shut off hot and cold water supply.
I. Replacing the cartridge (F), see fold-out page III, Figs. [9]
to [11].
Observe the correct installation position!
Ensure that the cartridge seals engage in the grooves of the
housing. Fit screws (G) and tighten evenly and alternately.
II. Diverter (D), see fold-out page III, Figs. [9] to [11].
Replacement parts, see fold-out page II (* = special
accessories).
Care
For directions on the care of this fitting, refer to the
accompanying Care Instructions.
5


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Grohe 29067 BauMetric at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Grohe 29067 BauMetric in the language / languages: English, German as an attachment in your email.

The manual is 0,46 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info