571678
2
Zoom out
Zoom in
Previous page
1/72
Next page
2 GMC-I Messtechnik GmbH
PROBE
54
SONDE
Auto
PE
3
2
HV
Function
Test
V
Aux
Setup
Iso
/
I leakage
BDFHK
AC E G I
Applied Parts
1
!
45678910
11
12
13
14 15 1816 17
Probe connection
Insert the double plug of the probe into sockets 4 and
5 such that the plug with the white ring contacts
socket 5 (vertical bar).
Note: Contact problems with exposed conductive parts
when using the standard probe with test tip
In order to assure good contact, surface coatings must be
removed from devices under test with special tools at a suit-
able location so that the surface has a metallic shine. The tip
of the test probe is not suitable for scratching away paint, be-
cause this may impair its coating and/or mechanical
strength. The brush probe (Z745G) may be more suitable
than the test probe in certain individual cases.
Measurements at jacks 1 – 2 – 3
Always start with the measurement before contacting
the measuring point. Between jacks 1 and 2, a maxi-
mum of 10 V may be applied. Between jacks 2 and 3,
up to 253 V may be applied.
Attention: Jacks (2) and (3) are short-circuited
during all measurements at the test socket!
(Exception: see chapter 12.2)
Standard equipment
1
Test instrument
1 Probe cable with test probe
1 Clip-on alligator clip for test probes
3 Clip-on quick-clamp terminals
1 Calibration certificate per DKD
1 Operating instructions
1Carrying strap
Up-to-date PC software (free start-up programs or
demo software for data management, report and list
generation) is available on our website for download.
!
These operating instructions describe an
instrument with firmware version 7.24.
RS232
IOIOI
24
23
22
21
25
22
26
27
20
19
max. 10 V
max. 253 V
SL
N
L
1
2
3
SECULIFE ST
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt SECUTEST SIII at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt SECUTEST SIII in the language / languages: English as an attachment in your email.

The manual is 0,82 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info