METRISO XTRA
High-Precision
Insulation, Low Resistance and Voltage Measurement Instrument
4 GMC-I Messtechnik GmbH
Data Interfaces
Type USB slave for PC connection
Type RS232 for barcode and RFID scanners
Applicable Regulations and Standards
Scope of delivery
1 Insulation and resistance measuring instrument
1 DAkkS calibration certificate
1 Set of batteries
1Carrying strap
1 Alligator clip
1 Cable set KS17-4
1USB cable
1 Condensed operating instructions
1 Supplement Safety Information
Detailed operating instructions for download from our website
at www.gossenmetrawatt.com
Accessories (not included)
Akku-Pack Master Z502H Charger Z502R
ISO Kalibrator 1
Calibration adapter for the
rapid, efficient testing of
the accuracy of measur-
ing instruments for insula-
tion resistanced and low-
impedance resistances.
Cable Set KS-C
Cable set consisting of
measurement cable and
high resistance measuring
cable, for measurements
in the G- range.
Cable Set KS24
Cable set KS 24 consists
of a 4 m long extension
cable with a permanently
mounted test probe at one
end and a contact pro-
tected socket at the oppo-
site end, as well as an alli-
gator clip for plugging onto
the test probe.
Telearm 1
IEC 61010-1/ EN 61010-1
VDE 0411-1
Safety requirements for electrical equipment for
measurement, control and laboratory use
Part 1: General requirements
(IEC 61010-1:2010 + Cor. :2011);
German edition EN 61010-1:2010
Part 31: Safety requirements for handheld measuring
and testing accessories
(IEC 61010-031:2002 + A1:2008);
German edition EN 61010-031:2002 + A1:2008
IEC 61557/ EN 61557/
VDE 0413
Part 1: General requirements (IEC 61557-1:2007);
German
edition
EN 61557-1:2007
Part 2: Insulation resistance (IEC 61557-2:2007);
German
edition
EN 61557-2:2007
Part 4: Resistance of earth conductors, protective con-
ductors and equipotential bonding conductors
(IEC 61557-4:2007); German edition EN 61557-
4:2007
Part 10:Electrical safety in low voltage systems up to AC
1000 V and DC 1500 V – Equipment for testing,
measuring or monitoring protective measures
(IEC 61557-10:2000);
German edition EN 61557-10:2001
EN 1081 Testing of electrostatic discharge capacity for floor
coverings in potentially explosive atmospheres
EN 60529
VDE 0470-1
Test instruments and test procedures
Degrees of protection provided by enclosures (IP code)
DIN EN 61326-1
VDE 0843-20-1
Electrical equipment for measurement, control and
laboratory use – EMC requirements –
Part 1: General requirements
with angle plug / jack plug
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRISO XTRA at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRISO XTRA in the language / languages: English as an attachment in your email.

The manual is 0,4 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gossen Metrawatt METRISO XTRA

Gossen Metrawatt METRISO XTRA User Manual - German - 38 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info