590607
2
Zoom out
Zoom in
Previous page
1/3
Next page
Diodentest
Diode Testing
V / V
Gelijk- / mengspanningsmeting
Direct Voltage / Pulsating Voltage Measurement
V~/ Hz
Wisselspanning – Frequentie, zonder/met laagdoorlaatfilter
AC Voltage – Frequency, without/with Low-pass Filter
m
Capaciteit
Kabellengtemeting
Capacitance Cable Length Measurement
A / A
Gelijkstroom- / mengstroommeting
DC / Pulsating Current Measurement
A~ / Hz
Wisselstroom- / frequentiemeting
Alternating Current / Frequency Measurement
COM mA A
V
Temp
aEb
Doorstroomrichting
Sperrichting
0V !
0.654
0.L
... 5,1 V
+
0.443
V
!
DC
Meetbereik:
Measuring Range:
Conducting Direction
Reverse Direction
FUNC
ENTER
000.8
R
SL
COM mA A
V
Temp
aEb
– (+)
+ (–)
V= : 100 V 610 V
020.00
V
DC
AC
TRMS
020.00
V
DC
V
V
V
V
Meetbereiken:
> 15 V AC of/or > 25 V DC:
> 610 V:
Waarschuwingen voor gevaarlijke spanningen:
230
.
0
Caution! Dangerous Voltages:
Measuring Ranges:
max. 600 V (< 10 kHz)
!
P
max
= 6 x 10
6
V x Hz
FUNC
ENTER
V : 10 mV610 V
CLiP = OFF ! SETUP
COM mA A
V
Temp
aEb
max. 600 V (< 10 kHz)
V~: 10 mV 610 V
Hz: 1Hz 300 kHz
~
!
>610V:
0225.6
V
AC
TRMS
0049.9
Hz
AC
V~
Hz
V~
Hz
V~/Hz & Filter
P
max
= 6 x 10
6
V x Hz
V~ FilFilter actief / active
Hz FilFilter actief / active
Meetbereiken:
Measuring Ranges:
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
CLiP = OFF ! SETUP
COM mA A
V
Tem p
aEb
10.38
F
0V !
!
+
+
10 pF ... 310 F
m
FUNC
ENTER
15.00
m
m
3.100 km/31.000 km
Meetbereiken:
Measuring Ranges:
COM mA A
V
Temp
aEb
k
Setup CAP
Kabeltype = constant !
!
Cable type = constant !
COM mA A
V
Tem p
aEb
~
R
x
~
R
x
1
3
2
Zekering
Fuse
FF 1,6 A / 700 V AC DC
6,3 mm x 32 mm
A
A
003.50
m A
DC
003.50
m A
DC
AC
TRMS
A
A
8
.
8
.
8
.
8
.
8
!
Stroom
Current
Meetbereiken:
Measuring Ranges:
FUNC
ENTER
!
I > 1,1 A
A: 0,1 A . .. 1,1 A
A: 3 A . .. 1,1 A
COM mA A
V
Tem p
aEb
Stroom
Current
~
R
x
~
R
x
1
3
2
A~
Hz
A~
Hz
003.50
m A
AC
TRMS
0049.1
Hz
AC
8
.
8
.
8
.
8
.
8
!
Zekering
Fuse
FF 1,6 A / 700 V AC DC
6,3 mm x 32 mm
Meetbereiken:
Measuring Ranges:
FUNC
ENTER
Hz: 1Hz
30 kHz
!
I > 1,1 A
A ~: 3 A . .. 1,1 A
A / Hz
Meting met stroomtang
Measurement with Current Transformer Clamp
M ISO @ 100 V / Hz
Isolatieweerstandsmeting
Insulation Resistance Measurement
Apparaat- en meetparameters SETUP
Device and Measuring Parameters
Technische gegevens – Technical Data
1)
bij / at 0 C...+40C
2)
als functie ZERO actief / with function ZERO active
3)
Vermogensbegrenzing /
Power limiting:
6 · 10
6
V · Hz (max. 600 V 1 kHz)
4)
voor maximale stroomwaarden, zie Stroommeetbereiken
max. current values see current measuring range
Elektrische veiligheid – Electrical Safety
Beschermingsklasse / Protection class II
– volgens /
per
IEC 61010-1:2010/EN 61010-1:2010/VDE 0411-1:2011
Meetcategorie / Measuring Category CAT I I / CAT III
Nominale spanning / Nominal Voltage 600 V / 300 V
Verontreinigingsgraad / Pollution degree 2
Testspa n ning / Te st Vol t age 3,5 kV~
– volgens / per IEC 61010-1/EN 61010-1
IP-classificering / Protection
– Behuizing / Housing: IP54 (drukcompensatie door
behuizing/pressure equalization
by means of the housing)
Tabellenuittreksel over de betekenis van de IP-code
Extract from table on the meaning of IP codes
Elektromagnetische compatibiliteit EMC
Electromagnetic Compatibility EMC
Storingsuitzending / Interference Emission
EN 61326-1:2006 Klasse B / class B
Storingsbestendigheid / Interference Immunity
EN 61326-1:
2006
EN 61326-2-1:
2006
Omgevingsomstandigheden – Ambient Conditions
Nauwkeurigheidsbereik / Accuracy range 0C ... + 40 C
Werktemperatuur / Operating temperature –10 C ... + 50 C
Opslagtemperatuur /
Storage temperature
zonder batterij / without battery – 25 C ... + 70 C
Relatieve luchtvochtigheid / relative humidity 40 ... 75 %
Geen condens toegestaan / no condensation allowed
Hoogte boven NAP tot / Elevation up to 2000 m maximum
Zekering – Fuse
FF(ultrarapid) 1,6 A / 700 V AC DC
6,3 mm x 32 mm
Uitschakelvermogen /
breaking capacity
: 50 kA (Min 10 kA)
Bij gebruik van een andere zekering vervalt de fabrieksgarantie.
If you use other fuses than the one indicated above you forfeit
your product guarantee.
Interne zekeringentest –
Internal Fuse Test
Zekering vervangen – Fuse Replacement
Koppel het apparaat van de meetkring af voordat u
het deksel van het zekeringenvakje openmaakt! Draai
daartoe de spleetschroef naar links. Deze kan niet ver-
loren gaan.Licht de zekering met de vlakke zijde van
het zekeringendeksel uit het vakje.
Als u het zekeringendeksel weer inzet, moet u de zijde met de
geleidehaken er het eerst inzetten.
Draai de spleetschroef naar rechts in.
Disconnect the instrument from the measuring circuit
before opening the fuse compartment lid! Turn the
(captive) slotted head screw counter-clockwise for
this purpose. Remove the fuse with the flat end of the
fuse compartment lid.
When refitting the fuse compartment lid the side with the guide
hooks must be inserted first. Then turn the slotted head srew
clockwise.
COM mA A
V
Te mp
aEb
* METRAFLEX
Overbren-
gingsverhou-
ding
Transforma-
tion ratio
CLIP
Meetbereiken
Measuring
Ranges
Tang
Current
sensor
300
mV
3 V 30 V
1:1
1mV/1mA
0,3 A
3 A 30 A
WZ12C
1:10
1mV/10mA 3 A 30 A 300 A
WZ12B
Z201A/B
METRAFLEX
1:100
1mV/100mA
30 A
300
A
3000 A
Z202A
/B
METRAFLEX
1:1000
1 mV/1 A
300
A
3000
A
(30kA)
WZ12C
Z202A/B
Z203A/B,*
~
R
x
0035
.
0
A
AC
TRMS
A~
Hz
1:1000
0050
.
1
Hz
AC
1:1000
SETUP
Stroom
Current
0035
.
0
A
1:1000
0035
.
0
A
1:1000
A
A
SETUP
DC
AC
TRMS
DC
TRMS
FUNC
ENTER
FUNC
ENTER
R
i
~ 9 M
R
i
V
V
V~
Hz
R
x
0V !
!
000.00
M
M
300 k/3 M/30 M/300 M
Meetbereiken:
Measuring Ranges:
a-b
a-E
b-E
M
ISO
@100V
COM mA A
V
Temp
aEb
ab
aE
Eb
ISO
a-b
FUNC
ENTER
UISO ON / OFF
ZERO
ESC
POL / UISO
FUNC
ENTER
UISO ON / OFF
a-E
FUNC
ENTER
UISO ON / OFF
ZERO
ESC
POL / UISO
FUNC
ENTER
UISO ON / OFF
b-E
FUNC
ENTER
UISO ON / OFF
ZERO
ESC
POL / UISO
FUNC
ENTER
UISO ON / OFF
short leads
00
.
00
voor de meting
before measurem.
a
a
b
b
E
E
UISO
bAtt: 2.92 V
verSion: 1.00
dAtE: 13.09.06
tiME: 11:15:19
OCCUP:
100.0%
... InFo
tEMP ...SEt
1nfo
Submenu's / Parameters / Sub-menus / Parameters
rAtE 0:05:00
0.diSP
0000.0/0.0
A.diSP
bArG/Point
CLiP
OFF/1:1...1000
APoFF
10...59min/on
U_ISo 100 V
CAP 10 ... 500nF
r_SL 100...3,1K
,
bEEP
01... 90
irStb ir on/oFF
Addr 01...15
dAtE 13.09.
tiME 11:15
C
F
Hoofdmenu's / Main Menus
opvragen instellen instellen
read set set
... SEnd ... StorE ...
bevestigen
confirm
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
FUNC
ENTER
MEASURE
SETUP
0
20
.
00
V
DC
AC
TRMS
Meetbereik
Measuring Range
Meetfout / Measuring Error
Overbelastbaarheid
1)
Overload capacity
/
300 mV
(
0,5% + 3 D)
2)
1,5% + 3 D
(> 300 D)
600 V
DC
AC
eff
Sinus/
sine
continu
continuous
3V
(
0,5% + 1 D)
1,5% + 3 D
(> 100 D)
30 V
300 V
600 V
1 Hz ... 300,00 kHz (0,5% + 1 D) 600 V
3)
max. 10 s
/
300 mA (0,5% + 5 D)
1,5% + 5 D
(> 100 D)
0,3 A
continu
continuous
3mA
(0,5% + 3 D)30 mA
300 mA
1A(0,5% + 5 D) 1,6 A 5 min
1 Hz ... 30,00 kHz (0,5% + 1 D)
4)
(... % v.d. meetw. + ... D)
300 0,5 + 3
2)
600 V
DC
AC
eff/rms
Sinus/
sine
max. 10 s
3k
0,5 + 1
30 k
300 k
3M
30 M 2 + 5
R
SL
300 3 + 5
R
SL
3k 3 + 5
300 3 + 5
5,100 V 2 + 5
30 nF (1 % + 6 D)
2)
600 V
DC
AC
eff
Sinus/
sine
max. 10 s
300 nF
(1% + 6 D)3 F
30 F
300 F (5% + 6 D)
IP XY
(1e cijfer X)
(1
st
digit X)
Bescherming tegen
binnendringen van vaste
vreemde deeltjes
Protection against
foreign object entry
IP XY
(2e cijfer Y)
(2
nd
digit Y)
Bescherming tegen bin-
nendringen van water
Protection against the
penetration of water
5
Stofvrij
dust protected
4
Spatwater
splashing water
Zekering defect
0fuse
A
DC
Fuse defective
?
Zekering testen
Test Fuse
A
A
A~
Hz
!
!
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRAHIT T-COM at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRAHIT T-COM in the language / languages: Dutch as an attachment in your email.

The manual is 0,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gossen Metrawatt METRAHIT T-COM

Gossen Metrawatt METRAHIT T-COM Quick start guide - English - 2 pages

Gossen Metrawatt METRAHIT T-COM User Manual - English - 72 pages

Gossen Metrawatt METRAHIT T-COM Quick start guide - German - 2 pages

Gossen Metrawatt METRAHIT T-COM User Manual - Dutch - 72 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info