590606
4
Zoom out
Zoom in
Previous page
1/4
Next page
GMC-I Messtechnik GmbH
Südwestpark 15
90449 Nürnberg •
Germany
Telefon+49 911 8602-111
Telefax +49 911 8602-777
E-Mail info@gossenmetrawatt.com
www.gossenmetrawatt.com
Erstellt in Deutschland • Änderungen vorbehalten • Eine PDF-Version finden Sie im Internet
Edited in Germany • Subject to change without notice • A pdf version is available on the internet.
Rédigé en Allemagne • Sous réserve de modifications • Vous trouvez une version pdf dans l’internet
Temperaturmessung – Temperature Measurement – Mesure de la température
Isolationswiderstandsmessung [M
] (nur METRA HIT 27I/H+E
CAR
)
Insulation Resistance Measurement [M
] (METRA HIT 27I/H+E
CAR
only)
Mesure de Résistance d’isolement [M
] (METRA HIT 27I/H+E
CAR
uniquement)
0023.2
C
sensr
pt1000 selCt
C

Pt100
FUNC
C / F
FUNC
00.10
rlead temp


Zuleitungs-
Widerstand
Pt1000 (TF220)
Ni100
Ni1000
0 50
+
pt1000
FUNC
RTD
Cable
Resistance
Résistance
de câble
RTD Messbereich / Measuring
Range / Gamme de mesure
Pt 100 200,0 + 100,0 C
+100,0 +600,0 C
Pt 1000 200,0 +100,0 C
+100,0 +600,0 C
Ni 100 60,0 +180,0 C
Ni 1000 60,0 +180,0 C
°C
FUNC
-
-
-
-
-
V
000 250
V
M@
50... 500V
10
.
29
V
251 250
V
M
gewählte Prüfspannung
Messspannung
Prüfspannung ausgeben
solange Taste gedrückt
R
ISO
/Restspannung
FUNC MAN
+
Dauermessung
R
ISO
U (50...500 V)
: 10 k 3G
!
Messbereich:
Measuring Range:
Gamme de mesure:
Measuring Voltage
/Residual Voltage
Tension de mesure
/Tension résiduelle
Continuous Meas.
Mesure de longue
selected Test Voltage
Tension d’essai sélectionnée
durée
Test voltage applied
as long as key is depressed
Tension d’essai appliquée
tant que la touch est enfoncée
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt METRA HIT 27I at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt METRA HIT 27I in the language / languages: English, German, French as an attachment in your email.

The manual is 0,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gossen Metrawatt METRA HIT 27I

Gossen Metrawatt METRA HIT 27I User Manual - English - 28 pages

Gossen Metrawatt METRA HIT 27I User Manual - Dutch - 28 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info