22 GMC-I Messtechnik GmbH
1)
The measurement is independent of the position of the selector switch for the voltage ranges.
Symmetry error of the delta voltage with power factor measurement on three-phase sys-
tems is 0.5% at a maximum.
2)
The measurement is of informative character only. That is why no class accuracy is given.
The indication is independent of the position of the selector switch for the voltage ranges.
6 Maintenance
6.1 Battery and Fuse Replacement
Caution: Disconnect the meter from the measuring circuits before
you open the battery compartment. Take care that the
cover is replaced before you operate the meter again.
Battery Replacement
If, when testing the battery, the pointer no longer reaches the battery
test section " ", the corresponding battery must be replaced.
Replace the exhausted battery with a new, 9-V flat cell battery 6F22,
6LF22 or 6LR61, as described in chapter 3.2 „Installing the batteries“.
Fuse Replacement
If a fuse blows, eliminate the cause of the overload before placing the
instrument back into operation!
Open the instrument as described under battery replacement.
Remove the blown fuse with the help of an object, such as a test
probe, and replace it with a new F25A 500V/1.5kA fuse.
Electromagnetic Compatibility EMC
Interference Immunity and Emission EN 61326
Mechanical Design
Display Moving-coil movement
Scale length 96 mm
Protection type IP 50 per VDE 0470 Partl 1
Dimensions 110 mm x 181 mm x 62 mm
Weight approx. 0.8 kg
!
22


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gossen Metrawatt MAVOWATT 4 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gossen Metrawatt MAVOWATT 4 in the language / languages: English as an attachment in your email.

The manual is 0,32 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info