ALARM AUTOMATIC ARMING.
To obtain this function, connect the YELLOW-GREEN wire to earth. The alarm will
automatically arm 30 sec, after the engine switching OFF and the door opening.
SELF-LEARNING OF AN ELECTRONIC KEY CODE (US MODELS)
Close the vehicle’s doors and disarm the alarm system. Turn the ignition key to ON and within
10 seconds put the electronic key to learn in the socket. The LED switches on for one second.
It is possible to learn a maximum number of 3 keys.
Note: if you put a learned key in the socket this will not annul the other memorised keys;
otherwise, if you put a new key in the socket the first memorised key will be annulled.
GARAGE POSITION (ONLY US MODELS).
With this function it is possible to leave the vehicle in the servicing or in the washing centres without
leaving the original transmitter or the electronic key to the staff. To obtain this function, connect the
yellow-green wire to earth.
ACTIVATION OF THE GARAGE POSITION.
1. Disarm the alarm, turn the ignition key to ON and open one door.
2. Turn the ignition key to ON and within 15 sec. put the electronic key in the socket. 2
pulses of the LED signal the activation of the function.
Note: put the key in the socket within the 15 seconds otherwise the procedure will
automatically annul.
3. Turn the ignition key to OFF position.
In this condition the engine of the vehicle can be switched on for 20 times without triggering
the alarm. The working of the GARAGE position is signalled through the fast flashing of the
LED if the ignition key is in ON position for more than 10 seconds.
BLINKER EXCLUSION WHILE ALARM ARMING/DISARMING
This function is necessary on vehicles with original flashing of the direction indicator lights
while opening and closing the door.
BLINKER EXCLUSION ACTIVATION.
Before supplying the alarm unit, turn the ignition key to ON position.
Supply the alarm system and turn the ignition key to OFF.
LED’S MEMORY
While alarm disarmed it is possible to verify if an alarm condition has occurred and to
determine the cause following the LED flashing.
LED signalling Alarm triggering
¬l¬ Internal sensors (only 7024US)
¬¬l¬¬ Doors pin switches
¬¬¬l¬¬¬ Ignition live
¬¬¬¬l¬¬¬¬ External sensors(Green-Black wire)
l LED OFF (2 sec.) ¬ LED ON (1 sec.)
The inhibit time is 30 sec. for each alarm triggering. Turn the ignition key to ON to stop the
LED flashing.
TECHNICAL DATA
Power supply 10,5 ÷14,5VDC
Max. current absorption 5 mA
Working temperature -30° + 85°
Contact capacity horn control 8A to 20° C
Contact capacity visualising signals 8A to 20° C
Contact capacity engine immobilisation 8A to 20° C
Alarm period 30 sec.
Max. current positive alarm armed (+A) 1A
Max. current comfort control 100mA
Max. number codifying keys 3 (only US models)
SELF-POWERED CODIFIED 7125TNC SIREN (US models)
DESCRIPTION
The self-powered codified siren is an audible signalling device with high power designed to be installed in
the engine compartment of the vehicles, which can be connected to the alarm unit through the wiring
harness supplied with the kit.
Wiring connections (for the installer) :
disconnect the negative of the battery and only re-connect after the installation is complete.
Wires Function
BLACK initialled RB ê Battery positive
BLACK initialled MB
ê Battery negative
BLACK initialled S
ê Gemini alarm PINK wire
BLACK initialled L
ê Gemini alarm BLUE wire
Connect one end of the BLACK initialled V wire to the bonnet button and the other end to the alarm unit
GREEN wire.
WORKING
The electronic siren 7125TNC is supplied with a self-powering internal device that allows the working of the
siren also in absence of the power or if the connection wires to the unit are cut.
Through the codified system between alarm and siren, the alarm activates and de-activates both the
battery charging and the power of the siren.
The battery recharges only with alarm disarmed. The self-power activates only with alarm armed and 3
minutes after the alarm disarming. Before de-activating the siren it is necessary to wait 4 minutes after the
alarm disarming.
MOUNTING
Mount the siren in the engine compartment of the vehicle using the screws and the bracket supplied with
the kit and a 8 mm adjustable wrench to tighten the nuts.
Mount the siren away from areas of intense heat and turn the acoustic ear trumpet to low.
Protects the wires from water and humidity isolating connection points with protective sheaths.
Technical data
Power supply 12 V
Current absorption alarm ON 3 mA
Current absorption alarm OFF 7 mA
Audible tone > 120 dB
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gemini 7024 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gemini 7024 in the language / languages: English as an attachment in your email.

The manual is 1,64 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info