479841
3
Zoom out
Zoom in
Previous page
1/7
Next page
Dip switch programming table.
1 ON Current drawn active
OFF Current drawn isolated
2 ON Acoustic activation/de-activation isolated
OFF Acoustic activation/de-activation active
3 ON Passive arming active
OFF Passive arming isolated
4 ON Locking control 1,5 sec.
OFF Locking control 25 sec.
TECHNICAL DATA
Power supply 12 VDC
Current drawn alarm ON 16 mA
Current drawn alarm OFF 14 mA
Working temperature -30° + 85°
Engine immobilisation relay contact capacity 8A to 20°C
Central door locking relay contact capacity 10 A to 20°C
Alarm cycle 30 seconds
Siren audible level at 1 meter in open space > 118 dB
Minimum power absorption required to trigger 5W
Current for control positive alarm armed 500 mA
This device has been designed to be fitted on all cars with a power supply of 12V and with
the negative connected to the body work.
Attention: do not turn the unit on with the key switch before the installation is complete. You
must then wait for a maximum of 60 minutes before completing the self-powered test. All
other alarm functions will perform as standard.
If You want to wash the engine of the car, please take care do not steam clean.
The manufacturer and his agents declines all responsibility for any possible defect or failure to the
device and to the vehicle’s electric system due to incorrect installation or to the alteration of the
indicated Technical Features. The alarm system has only a dissuasive function against possible
thefts.
Gemini Trading S.r.l. reserves the right to modify its products without prior notice.
ULTRASONIC MODUL DESCRIPTION
5023GE and 5123GE (for 4202RC-KT and 4203RC-KT)
The 5023 or 5123 sensors protect the vehicle passenger compartment, detect the
door opening or a movement in the passenger compartment and activate the alarm.
Installation instructions :
The connection with the alarm system is easy as the 4202RC and 4203RC wiring
harness is supplied with a connector for the connection of the sensor.
Put the connectors of the sensor’s ultrasonic heads in the appropriate seats : RED
for the connection of the TX head ; WHITE for the connection of the RX head.
Ultrasonic adjustment
- Lower one of the front windows approximately 20 cm.
- Adjust the sensor to a minimum sensitivity ;
- Activate the alarm pushing twice on the transmitter’s button (button 2) verifying all
doors are closed.
- Put an hand through the open windows and move it ; the LED will light
red. Increase the sensitivity till the alarm triggers.
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gemini 4203RC at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gemini 4203RC in the language / languages: English as an attachment in your email.

The manual is 1,6 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info