2. Safety Instructions
DANGER! Electric shock!
Risk of injury due to electric shock.
v Always unplug your Garden Pump before fil-
ling, after operation, when trouble-shooting
and before carrying out any maintenance work.
RISK OF INJURY!
Hot water – risk of scalding!
For pump 4000/5 only: If the pump is operated
for prolonged periods of time (> 5 min.) with
the delivery side closed, the water in the pump
may heat up so that there is a risk of scalding
yourself with hot water.
v The pump should not run against the closed
delivery side for more than 5 minutes.
If the water supply on the intake side of the
pump fails, the water in the pump can heat up
so that if water emerges, injuries could be
caused by the hot water.
v Disconnect the pump from the mains via
the main circuit breaker, let the water cool
and secure the suction-side water supply
before putting into operation again.
Location
Caution: Pursuant to DIN VDE 0100-702 and
0100-738, AS/NZS 3000 use of the pump nearby
swimming pools and garden ponds and other
similar places is only permissible if the pump is
operated via a residual-current device (FI switch)
with a residual current rating of ≤ 30 mA.
The pump must not be operated when there are
persons in the swimming pool or garden pond.
The pump must be located on solid, even ground,
protected from flooding. Take care that the pump
cannot fall into water. Position the pump at a safe
distance (min. 2 m) from the liquid to be pumped.
As an additional safety device an authorised safety
switch can be used.
v Please ask your electrician for his advice.
When connecting the pump to the water supply
system, the country-specific sanitary regulations
must be observed to prevent water not of drink-
ing water quality being drawn back in.
v Please consult a specialist for sanitary
installations.
Extension cables
Date indicated on the type plate must match
technical data of the mains supply.
Only use extension cables authorised in
accordance with HD 516.
v Consult your qualified electrician.
v Don’t use the power cable for carrying the
pump or for plugging off.
In Austria
In Austria, the electrical connections must be
made according to ÖVE-EM 42, T2 (2000) /
1979 §22 based on § 2022. Pursuant to this
regulation it’s imperative to operate pumps for
swimming pools and garden ponds exclusively
via an isolating transformer.
v Please ask your electrician.
In Switzerland
In Switzerland mobile appliances which are
used outdoors, must be connected via a residual-
current device.
Visual check
v Before operating the pump, first make a visual
cheek, if there is any damage of the pump
(esp. regarding power cable and plug).
A damaged pump must not be used.
v In case of damage, please have the pump
checked by our GARDENA Service Centre or
by an authorised electrician.
v A damaged connection cable may only
be exchanged by GARDENA Service or an
authorised electrician.
Please note:
The GARDENA Garden Pump is not suitable for continuous
operation (e.g. industrial applications, continuous circulat-
ingoperation). Corrosive, easily combustible, aggressive or
explosive liquids (such as gasoline, petroleum or nitro
thinner), saltwater and food must not be pumped.
The temperature of the liquid must not exceed 35 °C.
14
GB
3


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Gardena 5000-5 - 1734 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Gardena 5000-5 - 1734 in the language / languages: English as an attachment in your email.

The manual is 3,94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Gardena 5000-5 - 1734

Gardena 5000-5 - 1734 User Manual - German - 18 pages

Gardena 5000-5 - 1734 User Manual - Dutch - 17 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info