640551
2
Zoom out
Zoom in
Previous page
1/2
Next page
RS-1 AND RS-2 REMOTE SYSTEM CONTROL PANELS RS-1 AND RS-2 REMOTE SYSTEM CONTROL PANELS
R S - 1
MAINTAINED CONTACT
REMOTE CONTROL PANEL
The RS-1 Remote System Control Panel is an
attractively finished key switch designed for
use in single-gang wall mount boxes. It can
control, from one location, all Furman power
products that have
remote capability, such
as the Furman AR-PRO,
ASD-120, MiniPort-15,
MiniPort-20, PowerLink,
the PowerPort, PS-
8R, and the PS-PRO.
Multiple units can be
controlled simultane-
ously.
The RS-1 features a
two-position key oper-
ated switch, an indicator
LED, and can be easily
installed in any electrical switch box with a mini-
mum depth of 1-1/4”. On the rear is a printed
circuit board with a standard size terminal strip
for wiring connections.
The RS-1 may also be compatible with other
AC power distribution and sequencing prod-
ucts. Our Technical Support team will be
happy to advise you on your specific installa-
tion needs.
RS-1 SPECIFICATIONS:
Dimensions: 4.75” (H) x 2.75” (W) x 1.25” (D).
Finish: black epoxy powder coat.
R S - 2
MOMENTARY CONTACT
REMOTE CONTROL PANEL
The RS-2 Remote System Control Panel is
identical to the RS-1 in most respects, but with
a momentary function rather that maintained.
The key switch offers an enable/disable func-
tion.
The RS-2 can control
multiple power products
by wiring their control
inputs in parallel. The
RS-2 is ideal for instal-
lations requiring multiple
remote switches. For in-
stallations requiring only
one remote maintained
contact switch, we rec-
ommend the RS-1.
The RS-2 may also be
compatible with other AC power distribution
and sequencing products. Our Technical Sup-
port team will be happy to advise you on your
specific installation needs.
RS-2 SPECIFICATIONS:
Dimensions: 4.75” (H) x 2.75” (W) x 1.25” (D).
Finish: black epoxy powder coat.
RS-1 AND RS-2 WIRING
INSTRUCTIONS
Connecting the RS-1 or RS-2 Remote Control Panel
is easy. For the simplest of installations, a single pair
cable will suffice (standard 24-28 AWG telephone
wire is fine). This allows ON/OFF control only. To
enable the RS-1 or RS-2’s SYSTEM ON indicator, it
will be necessary to run a 2-pair cable.
Both Remote Control Panels are clearly labeled
on the rear panel adjacent to the terminal strip. For
single-pair wiring, connect the +V terminal of your
power product to the +V terminal of the RS-1 or RS-
2.
Next, connect the REM terminal of your power
product to the REM terminal of the RS-1 or RS-2,
and your installation is complete. Most newer Fur-
man products default to ON if the REM input is left
open or tied to GND. This allows normal front panel
operation if the unit is not being used with a remote
control panel.
It is recommended that where long wire runs (> 200
ft.) or noisy environments are encountered, 2-pair
cable be run, even if the indicator is not needed.
This allows rejection of AC noise and interference
by tying the REM input to GND when the unit is on.
For installations using 2-pair cable, +V and REM
connections are identical; just add wires from the
STAT terminal to STAT terminal, and GND terminal
to GND terminal.
Though the connection doesn’t require a shielded
cable, in particularly noisy environments a shielded
cable can be used by connecting the shield between
the GND terminals of the product and the RS-1 or
RS-2.
THREE YEAR
LIMITED WARRANTY
The Furman RS-1 and RS-2 are protected by a
limited three year warranty, covering defects in
materials and workmanship, provided that the
registration card is filled out and returned
by the
FPO
2


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Furman RS-1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Furman RS-1 in the language / languages: English as an attachment in your email.

The manual is 0,71 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info