OCCURRENCE SOLUTION
Wall plug disconnected. Push plug firmly into wall outlet.
Plug Current Device Tripped. Press the RESET button.
House fuse blown or circuit breaker tripped. Replace fuse with time delay type or reset circuit breaker.
Control is OFF. Turn Control ON and set to desired setting.
P1 appears in the display window. Drain water as described in Drainage Section.
Room Temperature lower than the set temperature (Cool Mode). Reset the temperature.
Room Temperature higher than the set temperature (Heat Mode). Reset the temperature.
Shut off in Heat mode. When the air outlet overheats, the automatic heat protection engages. Remove
any blockages and let appliance cool down. If the heating function can not be restarted after fully
cooling down, the thermal fuse may open the heater circuit, then call for service.
Air conditioner will not operate.
Air conditioner cooling, but room
is too warm - NO ice forming on
cooling coil behind decorative
front.
Dirty air filter - air restricted. Clean air filter. Refer to Care and Cleaning section.
Temperature is set too high. Set temperature to a lower setting.
Air directional louvers positioned improperly. Position louvers for better air distribution.
Front of unit is blocked by drapes, blinds, furniture, etc. - restricts air distribution. Clear blockage in
front of unit.
Doors, windows, registers, etc. open - cool air escapes. Close doors, windows, registers, etc.
Unit recently turned on in hot room. Allow additional time to remove “stored heat” from walls, ceiling,
floor and furniture.
Air conditioner turns on and off
rapidly.
Dirty air filter - air restricted. Clean air filter.
Outside temperature extremely hot. Set FAN speed to a faster setting to bring air through cooling coils
more frequently.
Before You Call
Air conditioner cooling, but room
is too warm - ice forming
on cooling coil behind decorative
front
Outdoor temperature below 16 °C (60 °F). To defrost the coil, set FAN ONLY mode.
Air filter may be dirty. Clean filter. Refer to Care and Cleaning section. To defrost, set to FAN ONLY
mode.
Temperature is set too low for night-time cooling. To defrost the coil, set to FAN ONLY mode. Then,
set temperature to a higher setting.
Ducts not connected or blocked. See HOSES INSTALLATION Section.
12
Room temperature below 16 °C (60 °F). Cooling may not occur until room temperature rises above
16 °C (60 °F).
Air from unit does not feel cold
enough.
Compressor shut-off by changing modes. Wait approximately 3 minutes and listen for compressor to
restart when set in the COOL mode.
Reset to a lower temperature.
2009 Electrolux Home Products, Inc. All rights reserved.
Noise when unit is cooling.
Air movement sound. This is normal. If too loud, set to lower FAN setting.
Vibration from uneven floor. Move or support appliance correctly on even surface.
Before calling for service, review this list. It may save you time and expense. This list includes common occurrences that are not
the result of defective workmanship or materials in this appliance.
If These Solutions Fail, Call 1-800-265-8352 For Frigidaire Service.
Room too cold.
Set temperature too low. lncrease set temperature.
Room too hot.
Set temperature too high. Lower setting.
12


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Frigidaire CPA123DU1 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Frigidaire CPA123DU1 in the language / languages: English as an attachment in your email.

The manual is 2,04 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info