This appliance must be installed by a qualified person in
accordance with local electrical safety rules and in compliance
with the manufacturer instructions.
Ensure that the voltage is the same as that stated on the rating
plate
placed on the inside of the front appliance drawer.
WARNING!THIS APPLIANCE MUST BE EARTHED
cleaning, but do not let it hang closer than 50mm (2») to the floor.
The cable can be looped if necessary , but make sure that it is not
kinked or trapped when the cooker is in position.
Open the mains terminal block cover as shown, unscrew the cable
clamp «A» and unscrew (not fully) the screws in the mains terminal
block «L N which secure the three wires of the mains cable.
Fit the cable and refit the cable clamp «A» (fig. N).
Allow sufficient cable length for the cooker to be pulled out for
Connecting the mains cable
* TAKING ACCOUNT OF CONTEMPORANEITY FACTOR OF 0,59
TYPE OF POWER SUPPLY
Different connections can be made simply by moving the jumpers on the
terminal board
2
1
3
4
5
L
N
A -
Cable Clamp
If an fixed appliance is not equipped with supply cable and plug, the
power supply must be fitted with a disconnect switch in which the
distance between contacts permits total disconnection in accordance
with overvoltage category III, as required by installation regulations.
Be sure that the earth wire green/yellow is not interrupted by the
switch
IMPORTANT
The wires in the mains lead are coloured in accordance with the
following code:
GREEN AND YELLOW........EARTH
BLUE....................................NEUTRAL
BROWN ...............................LIVE
REPLACEMENT OF THE CABLE
In case the cable is damaged, replace it in accordance with the
following instructions:
- disconnect the appliance from the electric network before any
intervention.
- open the box of the supply board as described on the picture N;
- unscrew screw A fixing the cable ;
- replace the cable with one of the same lenght and in accordance
with the features described on the table; switch the appliance off,
and close the gas tap
- the green-yellow earth wire must be connected to the terminal
  and it must be about 10 mm longer thean the live wires;
- the blue neutral wire must be connected to the terminal marked
with letter N;
- the live wire must be connected to the terminal marked with letter
L.
Appliance type Single-phase supply 230V~
Type of cable Section
Alla gas + double oven Rubber H05 RR-F or 3 x 2.5 mm
2
Ceramic work-top + double oven Rubber H05 RN-F
*
3 x 6 mm
2
Appliance type Two-phase supply 400V~
Type of cable Section
Ceramic work-top + double oven Rubber H05 RR-F or 4 x 4 mm
2
Rubber H05 RR-F
Appliance type Three-phase supply 400V~
Type of cable Section
Ceramic work-top + double oven Rubber H05 RR-F or 5 x 2.5 mm
2
Rubber H05 RN-F
Fig. N
WARNINGS
Isolate the cooker from the electricity supply before attempting to
replace the oven lamp.
The oven lamp used is of a special type withstanding high
temperatures. To replace it, act as follows: disassemble the protecting
glass (A) fig. 16 and replace the burnt lamp with one of the same
type. Reassemble the protecting glass.
ELECTRICAL CONNECTION
CERAMIC HOB
plates Ø mm Watt
E = GREEN and Yellow / N = BLUE / L = BROWN
400 V 3N~
5
4
3
2
1
L1
L2
L3
N
E
400 V
2
N~
5
4
3
2
1
L1
L2
N
E
230
V ~
5
4
3
2
1
L1
N
E
F 145 1200
G - I 180 1800
H 210 2200
L 265 1400/2200
G
H
F
I
L
APPLIANCE MAINTENANCE
Fig. 16
E 14
25 W - 230 V~
T300°C
A
35
GB
35


Need help? Post your question in this forum.

Forumrules
1

Forum

fratelli-onofri-yp-192.c50

Reset search

  • The gas button close the fire trough operation.
    All the other 3 working well

    Thanks Charlie +972 528898704 Submitted on 22-3-2022 at 16:46

    Reply Report abuse


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fratelli Onofri YP 192.C50 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fratelli Onofri YP 192.C50 in the language / languages: English, German, Dutch, French as an attachment in your email.

The manual is 0,77 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info