16
Voltage Measurement (355 only) 10 Hz to 100 Hz
600 and 1000 V ranges have 10 % over range to 660 and 1100 V respectively.
Range Resolution Accuracy Trigger Level for Hz
Filter OFF
Trigger Level for Hz
Filter ON
4 V 1 mV 1 % rdg + 10 digits 0.050 V 0.050 V
40 V 10 mV 1 % rdg + 5 digits 0.25 V 0.25 V
400 V 100 mV 1 % rdg + 5 digits 6 V 6 V
600 V AC RMS 1 V 1 % rdg + 5 digits 6 V 6 V
1000 V DC 1 V 1 % rdg + 5 digits N/A N/A
Voltage Measurement (355 only) 100.1 Hz to 1 kHz
600 and 1000 V ranges have 10 % over range to 660 and 1100 V
Range Resolution Accuracy
4 V 1 mV 3 % rdg + 10 digits
40 V 10 mV 3 % rdg + 5 digits
400 V 100 mV 3 % rdg + 5 digits
600 V AC RMS 1 V 3 % rdg + 5 digits
Ohms Measurement (355 only)
Range Resolution Accuracy
400 Ω 0.1 Ω 1.5 % + 5 digits
4 k Ω 1 Ω 1.5 % + 5 digits
40 k Ω 10 Ω 1.5 % + 5 digits
400 k Ω 100 Ω 1.5 % + 5 digits
24


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 353 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 353 in the language / languages: English as an attachment in your email.

The manual is 0,94 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 353

Fluke 353 User Manual - German - 26 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info