True-rms Digital Multimeters
Using Communications
55
Table 9. Stopped Recording Display
VAC
Start Time :
Duration : 3 days 14 Hrs 47 mins
Interval Samples: 135  Events:53
Reference: 121.70 VAC
06/10/07 07:23:55
Save Trend Close
Auto Range
500 VAC0
123.45 VAC
100 200 300 400
RecordingStoppedREL
1.75
8:10pm 06/13/07
1
2
3
6
54
est34.eps
Item Description
A Stopped Icon indicating the recording session is
stopped.
B Time and date when the recording began.
C Length (duration) of time recording session was
in progress.
D Number of event records detected.
E Reference value for relative measurements.
F Number of interval records detected.
Using Communications
You can use the IR communication link and FlukeView Forms
software to transfer the contents of a meter’s memory to a PC.
When using a PC-to-meter IR (infrared) communication link, refer
to the FlukeView Forms Installation Guide or the on-line help.
Note
The Meter will log in real-time mode to a connected
computer running FlukeView Forms. In addition, the
Meter allows the user to log to internal memory and
connect to the computer later for download.
FlukeView Forms allows you to place the data into standard
(default) or customized forms. The forms display the data in table
and graph form, as well as show user comments. You can use
these forms to satisfy ISO-9000 and other documentation
requirements.
65


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 289 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 289 in the language / languages: English as an attachment in your email.

The manual is 2,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 289

Fluke 289 User Manual - German - 92 pages

Fluke 289 User Manual - Dutch - 90 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info