Measuring AC and DC Signals
The Meter is capable of displaying both ac and dc signal
components (voltage or current) as two separate readings or one
AC+DC (rms) value combined. As shown in Figure 13, the Meter
displays ac and dc combinations three ways: ac displayed over
dc (AC,DC), dc displayed over ac (DC,AC), and ac combined
with dc (AC+DC). Select one of these three displays using the
Function and Mode menu.
With the rotary switch set to U, N, A, or X, press the
softkey labeled Menu. Move the menu selector to the menu item
labeled AC+DC. At this point, three different softkey labels
indicate AC+DC (F1), AC,DC (F2), and DC,AC (F3). Press the
softkey that presents these two signals as needed.
While in any of the three AC+DC modes, peak measurements,
frequency, duty cycle, and period measurements are not
allowed. In addition to these modes, MIN MAX, relative, and
relative % are not allowed in AC,DC or DC,AC modes.
Note
The bar graph is not displayed while the Meter is in
any of the three AC+DC modes.
Menu
123.45 VAC
AC over DC DC over AC AC + DC
VDC
23.45
Save Setup
Auto Range
500 VAC
Menu
125.66 V
VDC
23.45
Save Setup
AC + DC
500 V
Menu
23.45 VDC
VAC
123.45
Save Setup
Auto Range
500 V Auto Range
8:10pm 06/13/07
8:10pm 06/13/07
8:10pm 06/13/07
est30.eps
Figure 13. AC and DC Display
Both manual and autoranging is available when using the ac+dc
modes. The same range is used for both ac and dc signals.
However, while in autorange, up-ranging occurs when either the
ac or dc signal exceeds the present range. Down-ranging occurs
36


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 289 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 289 in the language / languages: English as an attachment in your email.

The manual is 2,15 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Fluke 289

Fluke 289 User Manual - German - 92 pages

Fluke 289 User Manual - Dutch - 90 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info