True-rms Multimeters
Display
5
F K Display hold enabled. Display freezes present reading. 115C & 117C
G M
VWX
MIN MAX AVG mode enabled.
Maximum, minimum, average or present reading displayed 115C & 117C
H (Red LED) Voltage presence through the non-contact VoltAlert sensor 117C
I LoZ The Meter is measuring voltage or capacitiance with a low input
impedance. 115C & 117C
J nµF mVµA
MkΩ kHz Measurement units. 115C & 117C
K DC AC Direct current or alternating current 115C & 117C
L N Battery low warning. 115C & 117C
M 610000 mV Indicates the Meter’s range selection. 115C & 117C
N (Bar graph) Analog display. 115C & 117C
O Auto Volts
Auto
Manual
The Meter is in the Auto Volts function.
Auto ranging. The Meter selects the range for best resolution.
Manual ranging. User sets the Meter’s range.
117C
115C & 117C
115C & 117C
P + Bar graph polarity 115C & 117C
Q 0L W The input is too large for the selected range. 115C & 117C
R LEAd W Test lead alert. Briefly displayed whenever the Meter’s
function switch is rotated to or from any A position. 115C & 117C
7


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Fluke 117C at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Fluke 117C in the language / languages: English as an attachment in your email.

The manual is 0,66 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info