5. AIR BY-PASS
Verify that the tubing to be used are clean inside, and free from any kind of impurities.
Connect the air circuit of the compressor to the circuit of the dryer (By-pass valve complete with unions),
respecting the position and the proper direction of the air flow.
The By-pass consists of a 4 ways distribution block, Rp ¾” threaded unions, and a manually operated piston
with an ergonomic handgrip. The piston has two positions:
Operating position (rod out): compressed air can flow through the dryers (dryer operating correctly).
BY-pass position (rod in): prevents the compressed air flow through the dryer (dryer under maintenance).
This do not prevents the possibility to utilize compressed air.
In case the system has to be moved, or for maintenance on the apparatus in absence of compressed air in
the dryer, proceed as follows :
Close the by-pass valve to insulate the dryer from the line;
Release completely the pressure from the dryer circuit pressing and holding down the TEST button on
the control panel (see chaper.3 paragraph.3.2);
Switch off the start switch and disconnect the dryer from electrical supply.
6. FILTERS FOR COMPRESSED AIR
6.1 RECOMMENDATIONS FOR INSTALLATION
This product has been designed and manufactured for compressed air treatment.
Each filter has an indestructible identification label on which the specifications for the filter usage are
indicated, together with the identification parameters of vessel and cartridge.
Each product is regularly tested before delivery.
In the filter, the air flow must always match the direction of the arrows present on the body.
Install the filter in vertical position, protecting it from fire, shocks and vibrations. To prevent damage to the
threading, never over tight the tubing, and never exceed pressure and temperature limits specified on the
filter. Never modify the filter without the authorisation of the manufacturer. The manufacturer will not be
liable in case on improper usage of the supplied devices.
The user is responsible for the treatment and the disposal of the condensate discharged from the
separation filter in compliance with laws and rules concerning pollution.
6.2 REPLACEMENT OF THE CARTRIDGE
a) Release the pressure from the filter as described in chapter 5
b) Carefully rotate the glass clockwise.
c) In case of bayonet type filter, once reached the stop point, withdraw the glass from the head.
In case of threaded type filter, unscrew completely the filter from the head.
d) Carefully unscrew the cartridge from the head.
e) Install the tensioning device of the old cartridge on the new one.
f) Reassemble the cartridge on the head, paying attention not to damage the sealing gasket.
g) Reassemble the glass on the head, caring that the two adhesive labels results vertically aligned.
h) Open carefully the valve intercepting the compressed air to start the treatment.
10


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Finicompressors Artic 134-25 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Finicompressors Artic 134-25 in the language / languages: English as an attachment in your email.

The manual is 0,19 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

Others manual(s) of Finicompressors Artic 134-25

Finicompressors Artic 134-25 User Manual - German - 11 pages


The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info