4
with the mains power supply voltage?
• Are power cords, insulation and plug in
good order: sound, not loose or
damaged?
• Is there a good, firm connection at the
mains socket?
• Does the drill show any sign of abnormal
running, overheating or excessive
sparking?
• Whenever any of the problems mentioned
above appear, immediately cease using
the machine and have it repaired by an
expert.
• Wear ear protectors. Exposure to noise can
cause hearing loss.
• Use auxiliary handles supplied with the tool.
Loss of control can cause personal injury.
Hold power tool by insulated gripping surfaces,
when performing an operation where the cutting
accessory may contact hidden wiring or its own
cord. Cutting accessory contacting a “live” wire
may make exposed metal parts of the power tool
“live” and give the operator an electric shock.

When using electric machines always observe the
safety regulations applicable in your country to
reduce the risk of fire, electric shock and personal
injury. Read the following safety instructions and
also the enclosed safety instructions.
Always check that the mains voltage is
the same as on the type plate of the
machine.
Class II machine – Double insulation –
You don’t need any earthed plug.
Replacement of power cords or plugs
Immediately dispose of old cords and plugs once
they have been replaced. It is dangerous to plug a
loose power cord into a mains power socket.
Use of extension leads
Only ever use approved extension leads that are
suitable for the power rating of the machine. The
mini mum core thickness is 1.5 mm2. Whenever
using a reel extension lead, always fully unroll the
lead.
Immediately switch off the machine when:
• Excessive sparking of the carbon brushes and
verticiliosis in the collector.
• Interruption of the mains plug, mains lead or
mains lead damage.
• Defect switch
• Smoke or stench of scorched isolation

Hammer drills require very little operator
pressure. Excessive pressure on the tool
can lead to unnecessary overheating of
the motor, and burning of the driven tool.

The auxiliary handgrip can be rotated 360º around
the drill head, enabling safe and comfortable
operation, for both left and right-handed users:
• Loosen the handgrip by turning it
anticlockwise.
• Rotate the handgrip to the desire position.
• Retighten the handgrip in the new position.
Exchanging and removing drill bits
Fig. A+B
Before exchanging bits, first remove the
power plug from the wall socket.
Inspect bits regularly during use. Blunt
bits should be re-sharpened or replaced.
• Lightly oil the bit shaft before inserting it into
the chuck.
• Slide the locking sleeve (11) to the rear, and
insert the bit into the chuck opening. Ensure
that the keyway in the bit is seated properly in
the chuck, by carefully turning the bit until it
clicks into place. Release the locking sleeve.
• To remove the bit, slide and hold the locking
sleeve to the rear.

• Loosen the handgrip by turning it anticlockwise.
• Insert the depth gauge ruler through the hole
in the auxiliary handgrip.
• Slide the ruler to the desired depth.
• Retighten the screw firmly.

Fig. D
The correct position of the selection switch for
4


Need help? Post your question in this forum.

Forumrules


Report abuse

Libble takes abuse of its services very seriously. We're committed to dealing with such abuse according to the laws in your country of residence. When you submit a report, we'll investigate it and take the appropriate action. We'll get back to you only if we require additional details or have more information to share.

Product:

For example, Anti-Semitic content, racist content, or material that could result in a violent physical act.

For example, a credit card number, a personal identification number, or an unlisted home address. Note that email addresses and full names are not considered private information.

Forumrules

To achieve meaningful questions, we apply the following rules:

Register

Register getting emails for Ferm HDM1023 at:


You will receive an email to register for one or both of the options.


Get your user manual by e-mail

Enter your email address to receive the manual of Ferm HDM1023 in the language / languages: English, German, Dutch, Danish, French, Italian, Polish, Portuguese, Swedish, Spanish, Norwegian, Finnish as an attachment in your email.

The manual is 12,86 mb in size.

 

You will receive the manual in your email within minutes. If you have not received an email, then probably have entered the wrong email address or your mailbox is too full. In addition, it may be that your ISP may have a maximum size for emails to receive.

The manual is sent by email. Check your email

If you have not received an email with the manual within fifteen minutes, it may be that you have a entered a wrong email address or that your ISP has set a maximum size to receive email that is smaller than the size of the manual.

The email address you have provided is not correct.

Please check the email address and correct it.

Your question is posted on this page

Would you like to receive an email when new answers and questions are posted? Please enter your email address.



Info